Step 4: Wiring the Inverter
975-0239-01-01
2–17
This manual for use by qualified personnel only
Accessing the AC Terminal Block and AC Ground Bar
All AC wiring connects to the AC terminal block located on the left-hand side of the
inverter beneath the AC access cover.
Figure 2-15
AC Terminal Block
xantrex
Hybrid Inverter /Charger
Gri d (AC1)
Gen (AC2)
Faul t /
Warning
Equal i ze
Battery
Chargi ng
I nverti ng
Flashing =
sell
When replacing the AC access cover,
ensure its recessed edge slips inside
the edge of the front panel.
Recessed
edge
Remove the two screws on the AC
access cover and slide it to the left of
the inverter to remove it.
AC
LOAD
GRID
(AC1)
GEN
(AC2)
AC OUT
AC IN
AC IN
L1
N
L2
L1
N
L2
L1
N
L2
AC Terminals
AC Ground Bar