Specifications and Characteristics
Electrical Specifications—Summary
Release 1.1
67
Table A.2
Drift Specifications for 6000 Watt units (10V to 60V Models)
Models
10–600
20–300
30–200
40–150
60–100
Drift (30 minutes):
1
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
4 mV
3600 mA
8 mV
1800 mA
12 mV
1200 mA
16 mV
900 mA
24 mV
600 mA
Drift (8 hours):
2
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
2 mV
240 mA
4 mV
120 mA
6 mV
80 mA
8 mV
60 mA
12 mV
40 mA
Temperature Coefficient:
3
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
3. Change in output per
°
C change in ambient temperature, with constant line and load.
4 mV
360 mA
8 mV
180 mA
12 mV
120 mA
16 mV
90 mA
24 mV
60 mA
Содержание XPR 10-600
Страница 2: ......
Страница 3: ...Operating Manual for XPR 6000 Watt Series Programmable DC Power Supply...
Страница 10: ...About This Manual viii Operating Manual for XPR Series Power Supply...
Страница 14: ...Contents xii Operating Manual for XPR Series Power Supply...
Страница 16: ...List of Tables xiv Operating Manual for XPR Series Power Supply...
Страница 18: ...List of Figures xvi Operating Manual for XPR Series Power Supply...
Страница 26: ...About The XPR Power Supply Rear Panel Connectors and Switch 24 Operating Manual for XPR Series Power Supply...
Страница 48: ...Installation Remote Sensing 46 Operating Manual for XPR Series Power Supply...
Страница 60: ...Operation Alarms 58 Operating Manual for XPR Series Power Supply...
Страница 79: ......