Specifications and Characteristics
Output Performance Specifications
74
Operating Manual for XPR Series Power Supply
Fall Time
For a programmed 95% to 5% step in output voltage.
Time Delay From Power On Until Output Stable
5 s maximum
(Within regulation envelope)
Time Delay From Output Enable Until Output Stable
2 s maximum
(Within regulation envelope)
Output Hold-Up Time – Power Off
Minimum 4 ms (at full load)
Output Hold-Up Time – Source Interruption
Minimum 4 ms with output deviation less than 5% of maximum output voltage after
source interruption.
Transient Response Time
1
Time to recover within 0.75% of rated output of previous level after step change in
load current between 50% and 100%.
Mode Crossover
Maximum deviation as a percentage of rated output voltage.
Peak–Peak and RMS Noise Bandwidth Limits
The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.
The frequency range for RMS measurements is 10 Hz–100 kHz.
Load Condition
Time (Max)
No Load
3 s
Full Load
50 ms
1. Time for the output voltage to recover within 0.75% of rated output of its previous level
after a step change in load current of up to 50% - 100% and 100% to 50% of rated
output
Mode
Time
Voltage Mode
3 ms
CV – CC Overshoot
1%
Содержание XPR 10-600
Страница 2: ......
Страница 3: ...Operating Manual for XPR 6000 Watt Series Programmable DC Power Supply...
Страница 10: ...About This Manual viii Operating Manual for XPR Series Power Supply...
Страница 14: ...Contents xii Operating Manual for XPR Series Power Supply...
Страница 16: ...List of Tables xiv Operating Manual for XPR Series Power Supply...
Страница 18: ...List of Figures xvi Operating Manual for XPR Series Power Supply...
Страница 26: ...About The XPR Power Supply Rear Panel Connectors and Switch 24 Operating Manual for XPR Series Power Supply...
Страница 48: ...Installation Remote Sensing 46 Operating Manual for XPR Series Power Supply...
Страница 60: ...Operation Alarms 58 Operating Manual for XPR Series Power Supply...
Страница 79: ......