Remote Operation
Making Connections for Remote Control
60
Operating Manual for XPR Series Power Supply
Making Connections for Remote Control
See
Figure 4.1
for the locations of the user and programming lines J1 and S1.
Figure 4.1
Location of J1 and S1
Remote
Shutdown
Using a
Contact
Closure
The interlock input may be configured for use with an external voltage free contact.
Connect pins as shown:
Table 4.1
Analog Pin Connections with a Contact Closure
Closing an external contact across the interlock pins A4/A5 will then enable the unit.
Opening the contact will disable the supply output.
Programming Line Pin #
User Line Pin #
J1-9
to
J1-12
J1-8
to
J1-11