11
2.0 INSTALLATION
©2000 Xantrex Technology Inc.
Figure 7
Suggested Mounting Method
Inverter Mounting
The DR Series inverter can weigh as much as 45 lb. (20.4 kg). Wallboard is not strong enough
to support its weight so additional support must be added. The easiest method for securing it to an
existing wall is to place two 2 x 4s horizontally on the wall (spanning at least three studs) and
securing the inverter to the 2 x 4s.
WARNING: USE APPROPRIATE LIFTING TECHNIQUES. HAVE EXTRA PEOPLE ON HAND TO
ASSIST IN LIFTING THE INVERTER INTO POSITION WHILE IT IS BEING SECURED.
Procedure
Locate the studs and mark their location on the wall.
Measure the desired height from the floor for the inverter to be mounted.
Using a level, run a horizontal line. The length of the line must span at least 3 studs.
Place a pre-cut 2 x 4 on the marked location and drill pilot holes through the 2 x 4s and
studs.
Secure the 2 x 4 with #10 wood screws (length to penetrate 1-1/2 inches into the studs).
Repeat the procedure for the remaining 2 x 4.
Wall studs 16 inches on
center
Wallboard
Floor
2 x 4 mounting
supports
Ceiling
975-0012-003
Approximately
4–5 ft
7–5/8" c-c
Inverter Mounting
(continued)