29
2.0 INSTALLATION
©2000 Xantrex Technology Inc.
FROM
UTILITY
120 VAC INVERTER OUT
MAIN PANEL
120 VAC FROM
INVERTER
UTILITY FEED
FROM METER
SUB PANEL
INVERTER/CHARGER
GROUND
NEUTRAL
120 VAC LINE IN
LINE OUT
120 VAC LINE OUT
NEUTRAL
GROUND
LINE OUT
NEUTRAL
GROUND
NEUTRAL
NEUTRAL
LINE
1
LINE OUT
GROUND
EXISTING HOUSE WIRING
120 VAC BACKUP POWER
TO LOAD
(NEW WIRING)
DISCONNECT
MAIN
BREAKER
NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
BREAKER BOXES VARY DEPENDING ON APPLICATION.
MAIN PANEL WIRING TO NON-CRITICAL LOADS
IS NOT ILLUSTRATED.
EARTH GROUND
120 VAC BACKUP POWER
TO LOAD
120 VAC
120 VAC
240 VAC
GROUND
CAUTION:
NEUTRAL BONDED TO GROUND
IN MAIN PANEL ONLY!
NEUTRAL
3597-W00-C06
Figure 25
Single Inverter 120 VAC Wiring Diagram
AC Wiring
(continued)
AC Input Wiring to the Main Utility Breaker Box
(single inverter installations)
WARNING: MAKE CERTAIN THE POWER TO THE MAIN UTILITY BOX IS DISCONNECTED!
NEVER WORK ON LIVE CIRCUITS.
Remove the MAIN UTILITY BOXs cover plate.
Connect the ground (green) wire to the GROUND bus in the main utility box.
Connect the neutral (white) wire to the NEUTRAL bus.
Connect the hot (black) wire to the 60 amp circuit breaker (installed for the inverter).
Torque all wires to the manufacturers specifications.
CAUTION: INSPECT ALL WIRING FOR PROPER INSTALLATION BEFORE REINSTALLING THE
COVER PLATE.
Содержание Trace DR Series
Страница 1: ...Installation Operator s Manual DR Series Inverter Charger ...
Страница 2: ......
Страница 81: ......
Страница 82: ......
Страница 83: ......