4–2
975-0390-01-01
Display Panel Operation
The
Freedom HF
features a display panel with three-digit LED display to
show inverter, AC source, and battery status information.
Feature
Description
1
Inverter button
•
Press and hold for one second to turn the
Freedom HF
’s Inverter function ON or OFF
(when AC Shore Power is NOT present.)
•
Press and hold for five seconds to go into Charger Current Select Mode.
2
Three-digit LED display screen
shows status information and fault codes.
3
Status LED
Indicates the mode of operation with a three-color LED.
•
Green
pertains to
Utility
status.
• Solid indicates the
Freedom HF
is in shore power mode and battery is fully charged.
• Flashing indicates the
Freedom HF
is in shore power mode and the unit is currently
charging the battery.
•
Yellow
pertains to
Battery
status.
• Solid indicates the
Freedom HF
is in inverter mode and using the battery to provide
AC power.
• Flashing indicates the
Freedom HF
is in inverter mode but AC shore power is
detected thus transferring to shore power mode within 20 seconds.
•
Red
indicates a
Fault
condition and the
Freedom HF
has shut down. See
“Troubleshooting Reference” on page 5–8
.
4
Select button
•
In Inverter mode, press the button to choose what appears in the three-digit LED
display:
Input Voltage
,
Input Current
, or
Output Power
. See
“To change the
inverter mode setting:” on page 3–5
.
NOTE:
A corresponding LED lights up for each of the three items.
•
In an Alarm condition, press and hold for two seconds to disable (or enable) the audible
alarm. See
“To adjust the alarm setting:” on page 3–5
.
•
In Charger Current Select Mode, press to select the charger current. See
“To change the
charger’s charging current setting:” on page 3–4
.
FREEDOM
HF 1000
Input Voltage (V)
Select
STATUS
Battery
Fault
Utility
Input Current (A)
Output Power (kW)
4
1
2
3
Freedom HF 1000
shown
See NOTE in Feature # 4 below.