Independent Power System
975-0390-01-01
1–3
Overload
Alarm and
Shutdown
During Inverter mode, the
Freedom HF
automatically alerts you if the
loads that are connected and drawing power from the unit are close to the
maximum operating limit.
The
Freedom HF
automatically shuts down when the maximum operating
limit is exceeded.
Over-temp
Alarm and
Shutdown
During Inverter mode, the
Freedom HF
automatically alerts you if it is
overheating and approaching the over-temperature shutdown limit.
The
Freedom HF
automatically shuts down when the limit is exceeded.
Independent Power System
Your
Freedom HF
has been designed to be the heart of a sophisticated,
independent power system. While the
Freedom HF
is an extremely
“friendly” product to operate, Xantrex wants to ensure that you get the
best performance from your system.
Inverting
Freedom HF
produces 120 Vac from your 12V batteries and is capable of
starting heavy loads like refrigerators and pumps.
When the
Freedom HF
is inverting (producing 120 Vac output) without a
load, it draws less than 1A of current from the battery (or battery bank).
This feature allows the unit to operate without draining too much stored
energy.
Charging
For the inverter to perform effectively, the batteries must be charged
correctly. The unit has a built-in three-stage charging system that extends
the life and optimizes the performance of the batteries.
In addition to the numerous features which let you maximize your
battery’s life and performance, the
Freedom HF
—unlike many
chargers—also has the ability to recharge batteries even if the voltage is
near zero (sometimes called dead battery charging).