3–6
975-0390-01-01
4. Continue pressing the Select button to cycle through the two settings
– “
AL0
” and “
AL1
” until you reach the desired setting.
5. Press and hold the Select button for five seconds to make the setting
permanent.
To adjust the under voltage shutdown setting:
By default the
low voltage
setting is set to
Low.
Low (“
sdL
”) sets the under voltage shutdown threshold to 10.5 V.
High (“
SdH
”) sets the under voltage shutdown threshold to 11.8 V.
1. Press and hold the Power button for five seconds.
2. Press the Power button three times.
The LED screen will flash “
Sd
” intermittently.
3. Press the Select button once.
The LED screen will display the present (or most recent) low voltage
setting.
Example, “
SdL
” for a low shutdown voltage setting.
4. Continue pressing the Select button to cycle through the two settings
– “
SdH
” and “
SdL
” until you reach the desired setting.
5. Press and hold the Select button for five seconds to make the setting
permanent.
To return all feature settings to factory default settings:
1. Press and hold the Power button for five seconds.
2. Press the Power button four times.
The LED screen will flash “
def
” intermittently.
3. Press and hold the Select button for five seconds to return all feature
settings to their factory default settings.