3–4
975-0390-01-01
To change the charger’s charging current setting:
By default the
charging current
is set to 55 A.
1. Press and hold the Power button for five seconds.
The LED screen will flash “
Cur
” intermittently.
2. Press the Select button once.
The LED screen will display the present charging current setting.
Example, “
40A
” for a 40 A setting.
3. Press the Select button again to change to the next setting.
The LED screen shows the next setting. Example, “
2A
” for a 2 A
setting.
4. Continue pressing the Select button to cycle through each of the four
settings – “
2A
”, “
10A
”, “
20A
”, and “
40A
” until you reach the desired
setting.
5. Press and hold the Select button for five seconds to make the setting
permanent.
Table 3-1
Charging Current Guidelines
AC Input Circuit Breaker
or fuse size
(Amps)
Charger DC Current
Setting
(Amps)
Maximum By-pass AC
Current Available
(Amps)
15
5
12.5
15
9.5
35
4.0
55
0
20
5
17.5
15
14.5
35
9.0
55
5.0
30
5
27.5
15
24.5
35
19.0
55
15.0