LED Status Indicators and Power Button
975-0999-01-01
15
Item LED Name
Steady
Flashing
Off
3
DC/DC
Converter
LED
The 48VDC-to-12VDC converter function is
enabled.
n/a
The 48VDC-to-12VDC converter
function is disabled.
4
Alert LED
An event condition such as ground fault or error
is detected requiring attention and user
intervention. Inverter and/or charging operation
stops until the user is able to remedy the event
condition and clear the Alert LED using the
optional Freedom EX Remote Panel (PN: 808-
0817-03). See also
and
An event condition, such as a
warning is detected but does not
require user intervention. Inverter
and/or charging operation may
temporarily stop but resumes
when the event condition
recovers by itself.
No events are detected.
5
Power
[Standby]
button
Press to switch to Battery/Inverter mode when shore power is not present and the house battery is sufficiently charged.
When in Shore mode, the button has no function. It does not control AC power from being passed-through to the load.
Charger mode turns on automatically and operates in parallel with Shore mode when shore power is qualified and the
battery is not fully charged.
NOTE
: Shore power refers to the AC input power from a utility grid, generator or external AC source. An event occurs when the unit
detects a condition such as an overload, over-temperature, or a ground fault. An event can recover automatically or manually with user
intervention.