AC/DC Panel
975-0999-01-01
9
Feature
Description
4
DC terminal
opening for routing (–) negative DC
cable for inverting from or charging a 48V battery.
5
DC terminal
opening for routing (+) positive DC
cable for inverting from or charging a 48V battery.
6
Single opening to
two DC output terminals
for
routing (–) negative and (+) positive DC cables for
12V DC loads.
c
Do not use for charging.
7
Grounding lug
provides a ground path for the
Freedom EX 4000 chassis to the DC system ground.
See WARNING.
8
Cooling fans
turn on when the internal temperature
reaches a set point temperature.
9
Mounting flanges
on both sides allow you to mount
the inverter/charger/converter permanently on the
interior deck or on a wall.
WARNING
ELECTRICAL SHOCK HAZARD
n
Use a torque screwdriver to tighten the bolt on the DC
ground lug to a torque of 23 in-lb (2.6 N-m) of force.
n
Apply an anti-corrosion compound to the copper wire prior
to connecting to the DC ground lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.