Specifications
A–6
975-0012-01-02 Rev A
Auto Low Battery
Protection enabled
11 V
11 V
22 V
22 V
DC Charger Rate
(Adjustable)
0 to 70 amps
0 to 35 amps
0 to 17.5 amps
0 to 70 amps
Common Specifications:
Voltage Regulation
(maximum)
± 5%
Voltage Regulation
(Typical)
±2. 5%
Waveform
modified sine wave
Load Power Factor
(allowed)
0.5 to 1.0 (leading or lagging)
Adjustable Load
Sensing Range
5 watts minimum to 100 watts maximum
Series Operation
NO
Force Air Cooling
Variable speed fan
Automatic Transfer
Relay
20 amps
Number of Charging
Profiles
10
Three-stage Charging
Yes (float, absorption, bulk)
Temperature Comp
Probe (BTS)
optional
Remote Control (RC8)
d
optional
a.Specifications subject to change without notice.
b.This is the minimum AC current required to obtain full pass-through and maximum battery charging.
c.Product may not meet voltage regulation specifications at other than "Input Nominal" at full-rated load.
d.Also compatible with the RC4.
Table A-3
Electrical Specifications for the DR Inverter/Charger
a
- 230 Vac/50 Hz Models
Model
DR1512E
DR1524E
DR1548E
DR2424E
Содержание DR1512W
Страница 2: ......
Страница 3: ...DR Inverter Charger Installation and Operation Manual...
Страница 10: ...viii...
Страница 18: ...xvi...
Страница 32: ...Installation 2 8 975 0012 01 02 Rev A Figure 2 3 On Grid Configuration with Renewable Energy Sources...
Страница 38: ...Installation 2 14 975 0012 01 02 Rev A Figure 2 9 DC Grounding...
Страница 57: ...3 Operation Chapter 3 Operation contains information about how to operate the DR Inverter Charger...
Страница 82: ...4 6...
Страница 90: ...A 8...
Страница 108: ...B 18...
Страница 120: ...IX 2...
Страница 121: ......