Front Panel Controls and Indicators
975-0012-01-02 Rev A
3–15
Circuit Breakers
The DR Inverter contains two circuit breakers located on the right-hand side of the
chassis, directly above the AC input terminal block. The pass-through AC input
circuit breaker protects the AC wiring and connected load. The charger AC input
circuit breaker protects the charger circuit. The breakers are rated for the
maximum charge rate and pass-through current allowed according to the rating of
the internal relay.
Table 3-4
AC Pass-through Circuit Breakers
Models
DR15XX
DR24XX
DR36XX
120 Vac
30 amps
30 amps
30 amps
210-230 Vac
15 amps
15 amps
N/A
Table 3-5
Battery Charger Circuit Breakers
Models
DR15XX
DR24XX
DR36XX
120 Vac
20 amps
30 amps
30 amps
210-230 Vac
8 amps
15 amps
N/A
Figure 3-12
AC Pass-through and Charger AC Input Circuit Breakers
AC Pass-through
Circuit Breaker
Charger AC Input
Circuit Breaker