M99 minifant operating instructions
Version M99E from 20.02.2014
Page 16 of 35
3.7.2
Open blowing church dome
When damp spraying a church dome of an aver-
age vertical height of approx. 15 m with a hose
length of approx. 40m in conjunction with a 2 ½‘‘
terminator, with the settings
Material : Level
6-8
Air
:
90 - 100% (max. power)
Processing rate of 270 kg/h to 410 kg/h can be
achieved.
3.7.3
Dry injection of cotton insulation in to a
wall.
For a wall with an average vertical height of approx.
11m and a hose length of approx 30m, with the
settings
Material : Level
6
Air
:
100% (max. power)
an insulation density of approx. 30 kg/cbm with a
processing speed of approx. 30 kg/h can be attai-
ned.