![Wylie Row Wyng Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/wylie/row-wyng/row-wyng_operators-and-parts-manual_1001711021.webp)
17
Note: If the sprayer is equipped with a return/mixing
line, only open this valve fully when mixing chemical
in the spray tank. This valve can be partially opened
during spraying to control the pump pressure. Fully
opening during spraying will prevent the boom from
achieving operating pressure.
Turn the pump off, close the spray tank ball valve and clean
out the main strainer.
Filling The Fresh Water Tank
Only potable water should be added to the fresh water
tank. Addition of contaminated water could cause bodily
injury when used for washing hands, face and eyes.
VersaTrakr, VersaTrail, 1600 --
Remove the cap from the
fresh water tank fill valve and couple the supply line. Open
the fresh water tank fill valve and open the supply line.
When the tank is full, close the fresh water tank fill valve
before disconnecting the supply hose.
WyngTrakr/1,000 Field Sprayer, 3 Point --
The fresh
water tank is filled by inserting a supply hose through the
fillwell on top of the tank.
The fresh water tank can be used for flushing the pump
and boom as well as supplying hygiene water for washing
hands, face and, if necessary, eyes.
Open the fresh water hygiene valve as needed to wash
hands, face or to flush eyes if contacted with chemical.
Figure C8
Filling Fresh Water Tank
< Open Fresh W
ater
< Open Fresh W
ater
Tank V
alve
Tank V
alve
Fresh Water >
Fresh Water >
Supply Line
Supply Line
Figure C9
Washing Hands From Fresh Water Tank Faucet
Loading Spray Material Into The
Sprayer
Spraying solution can be loaded by either filling with a pre-
mixed solution or mixing the chemical and carrier on the
sprayer. Most trailer mounted sprayers have a Handler™
mix tank mounted on the trailer while most 3 point sprayers
use the mix tank on the nurse trailer.
3 Point Row Wyng Carrier:
Remove the cap from the spray tank “Quick Fill” coupling
and attach the supply hose to the coupling. Open the “Quick
Fill” ball valve as well as the supply line. Fill the spray tank
with water or mixed solution.
If you are mixing the chemical in the spray tank, carefully
add the desired amount of chemical to the spray tank. Turn
the pump on and allow the agitator to circulate the chemical
for several minutes.
Figure C10
Filling 3pt Row Wyng
< Fill V
alve Open
< Fill V
alve Open
Supply Hose >
Supply Hose >
Valve Open
Valve Open
Sprayer Operation