Preparing Sprayer for Operation
Add about 10 gallons of water to the spray tank. Do not add
any chemical until the sprayer has been checked for proper
operation. Do not install spray tips in the nozzle bodies on
the boom until the lines have been flushed.
Open the gate valve located beside the line strainer. Check
for any leaks from the tank to the pump. Any fluid leak on
the suction side of the pump will result in an air leak when
the pump is started.
Check to see that the Hypro control valves are in the “off”
position (see Figure C6). Flip the toggle switch “on”. The
Remco pump will operate until the on-demand switch turns
the pump off at 60 psi.
The operating pressure is set by adjusting the pressure relief
valve (green knob) located on the top of the Hypro control valve.
Tighten the pressure relief valve to increase the pressure.
Example: To set the pressure for the trigger gun, engage
the valve handle and the trigger gun. Note the pressure
gauge. To increase pressure, screw the pressure adjust-
ing knob “in”; to decrease pressure, screw the knob “out”.
Utility Inspection & Setup
Note: The pressure for the 12 volt Remco pump can
only be adjusted up to the preset pressure (60 psi) of
the pump switch.
In order to check the operation of the optional Flat Fold
boom rotate the valve handle “up” that supplies the boom.
Water should be flowing from the boom nozzles. Allow
the water to flow for a few moments to flush any debris
from the lines.
Install the tips, screens and caps as shown in Fig. C8. Make
sure the spray pattern of the tip is in line with the boom so
the spray pattern will overlap between adjacent tips. The tip
screen is the final filter before the fluid passes through the
tip. If a single nozzle does not spray a proper pattern, the
tip screen should be checked and cleaned.
The operating pressure is set by adjusting the pressure relief
valve (green knob) located on the top of the Hypro control
valve as shown in Fig. C7. Tighten the pressure relief valve to
increase the pressure.
Figure C6
“Off” Control Valves
“On” Control Valves
Green Knob >
Figure C7
Adjusting Pressure Relief Valve
Pressure Adjusting >
Relief Valve --
Green Knob
Figure C5
Open Gate Valve
Gate Valve >
Figure C8
Installing Tips and Screens
Содержание Defender 3 Pt Sprayer
Страница 4: ......
Страница 27: ...23 Hypro Pump Information Hypro Pump Information...
Страница 28: ...24 Hypro Pump Information Hypro Pump Operation Maintanence Con t...
Страница 29: ...25 Hypro Pump Information...
Страница 30: ...26 Hypro Pump Information...
Страница 31: ...27 Hypro Pump Information...
Страница 32: ...28 Hypro Pump Information...
Страница 33: ...29 Remco Pump Information...
Страница 34: ...30 Remco Pump Information...