15

Connecting 12 Volt Pump to Power

The 12 volt Remco pump is an on-demand pump that will 

automatically shut off when the discharge valve is closed. 

The pump can be wired permanently with a toggle switch 

to turn power on or off to the pump (red wire is positive (+), 

black wire is negative (-)).

Installing the Flat Fold Boom

The  Utility  Skid  may  be  equipped  with  an  optional  Flat 

Fold boom that mounts in the receiver hitch of a pickup or 

utility vehicle. 
Insert  the  boom  mount  into  the  vehicle  receiver  hitch, 

then slide the boom over the boom mount and pin at the 

desired spraying height. Tighten the spreader bolt on the 

boom mount to remove any slack inside the receiver hitch. 

Tighten the jam nut.  

Fit the supply hose to the “T” hosebarb and secure with 

a hose clamp. 

Your Wylie Utility Skid Sprayer was manufactured to the 

highest  standards  of  quality.  It  is  necessary  though,  to 

check  to  make  sure  that  nothing  was  damaged  during 

shipping. Check bolts and fasteners for tightness.  Check 

the pump and plumbing for any signs of damage. 

Utility Skid Sprayer Inspection & Setup

Your Wylie Utility Skid Sprayer was completely assembled 

and should not need any additional assembly before use. 

The 50 or 100 gallon Utility Skid Sprayer can be mounted 

in a pickup or utility vehicle and is equipped with “L” bracket 

tiedowns. The  four  tiedown  brackets  and  hardware  are 

bagged and shipped inside the tank.  

Set the skid in the desired location in the bed of the vehicle, 

mark and drill ½” holes in the bed and the skid frame. Install 

and tighten the nuts and bolts. 

Utility Skid Sprayer Inspection and Setup

Figure C2 

Utility Skid Tiedown

< Tiedown Bracket

Figure C4

Flat Fold Boom Receiver Hitch Mounting

Red (Po) Wire >

< Black 

   (Negative -) Wire

< Pressure Switch

< Receiver Hitch

< Boom Mount

Boom Mount Tube >

Figure C3

12 Volt Pump Wiring

Figure C1

Utility Skid Sprayer

< “T” Hosebarb

<  ½” Supply Hose

Utility Inspection & Setup

Содержание Defender 3 Pt Sprayer

Страница 1: ...r s Parts Manual Defender 3 Pt Sprayer LGS 50 Trailer Sprayer Utility Skid Sprayer Deluxe Lawn Garden Trailer Sprayer Printed In The USA Specifications Design Subject To Change Without Notice 5 1 19 0...

Страница 2: ...to the LIMITED WARRANTY Polyethylene and fiberglass tanks These tanks are warranted for the storage and transport of water herbicide solutions on farm liquid fertilizer and liquid feed Such tanks sho...

Страница 3: ...r Frame Serial Number Pump Model Wylie Invoice Number Owner s Name Address City State Zip Phone Email Dealer Owner s Signature Must be returned within 10 days to validate the warranty Owner Registrati...

Страница 4: ......

Страница 5: ...on Setup 18 19 Sprayer Operation 19 20 Troubleshooting Guidelines 22 Hypro Pump Information 23 28 Remco Pump Information 29 30 Repair Parts 31 47 Defender Tank and Frame Assembly 32 Defender Pump and...

Страница 6: ...oderate injury NOTICE Indicates information considered important but not hazard related e g messages relating to property damage SAFETY INSTRUCTIONS Indicates a type of safety sign where specific safe...

Страница 7: ...holes Reduce speed when turning crossing slopes and on rough slick or muddy surfaces Be aware of where you are going at all times especially at row ends roads and around trees Do not permit others to...

Страница 8: ...4 Safety Decals Placement Safety Issues Decal V9055 Decal SW700 LGS 50 Utility Skid Sprayers Decal V9020 Decal SW701 Decal SW701...

Страница 9: ...where and how to make necessary adjustments to your sprayer for safe and proper operation Thoroughly read and understand the contents of this manual before operating your sprayer If you have questions...

Страница 10: ...f the tractor and sprayer hitch must be the same for the sprayer to mount properly Back the tractor to the sprayer Make sure that other people are clear of the area Pin the lower lift arms of the trac...

Страница 11: ...water to flow for a few moments to flush any debris from the lines Rotate the valve handle to open the valve that supplies the trigger gun Engage the trigger gun Check for any leaks in the sprayer sy...

Страница 12: ...fender sprayers the 10 boomless nozzle is standard without a boom Refer to the specific tip chart if a specialty nozzle is used Spray Boom Example Select the section of the chart for 11002VS yellow ti...

Страница 13: ...9 3 17 2 15 4 14 0 12 9 11 9 11 0 10 3 9 7 40 0 30 22 3 19 8 17 8 16 2 14 9 13 7 12 7 11 9 11 1 50 MESH 50 0 34 24 9 22 1 19 9 18 1 16 6 15 3 14 2 13 3 12 4 BLUE 60 0 37 27 2 24 2 21 8 19 8 18 2 16 8...

Страница 14: ...sulting in an improper spray pattern Chemically resistant rubber gloves must be worn when cleaning the line strainer Failure to do so could result in chemical exposure causing serious injury End of Da...

Страница 15: ...articular Attention To All Safety Suggestions Their purpose is to assure safe operation of the sprayer and prevent injury or damage to yourself or the unit LGS 50 Introduction Introduction LGS 50F Spr...

Страница 16: ...trigger gun Check for any leaks in the sprayer gun system The operating pressure is set by adjusting the pressure relief valve green knob located on the top of the Hypro control valve Tightenthepress...

Страница 17: ...al TeeJet broadcast tapered spray nozzle 11002VS yellow tip is standard for the boom on LGS 50 sprayers Refer to the specific tip chart if a specialty nozzle is used Spray Boom Example Select the sect...

Страница 18: ...sary adjustments to your sprayer for safe and proper operation Thoroughly read and understand the contents of this manual before operating your sprayer If you have questions or do not understand parti...

Страница 19: ...ity It is necessary though to check to make sure that nothing was damaged during shipping Check bolts and fasteners for tightness Check the pump and plumbing for any signs of damage Utility Skid Spray...

Страница 20: ...ob in to decrease pressure screw the knob out Utility Inspection Setup Note The pressure for the 12 volt Remco pump can only be adjusted up to the preset pressure 60 psi of the pump switch In order to...

Страница 21: ...ip is standard for the Flat Fold Boom Refer to the specific tip chart if a specialty nozzle is used Spray Boom Example Select the section of the chart for 11002VS yellow tips The ground conditions wil...

Страница 22: ...arest Wylie Spray Center or call Wylie Manufacturing at 888 788 7753 Please keep this manual handy to answer questions you may have as they arise Pay Particular Attention To All Safety Suggestions The...

Страница 23: ...convenient location on the tow vehicle Attach the brown wire to a ground source using a quick splicer or a vinyl ring terminal Cut the red wire attach both ends to the toggle switch with the female pu...

Страница 24: ...Fig D6 The cap snaps into place with a quarter turn which aligns the spray tip The tip screen is the final filter before the fluid passes through the tip If a single nozzle does not spray a proper pa...

Страница 25: ...people and animals are clear of the spray zone Flip the toggle switch On to start the pump Align the sprayer with the area to be sprayed and turn the boom ball valve On The Remco pump will average abo...

Страница 26: ...PTO engine speed Controller gun or nozzles do not operate Defender LGS 50 Utility 1 Control valve handle not engaged 2 Wrong control valve engaged 3 Malfunctioning controller 1 Rotate handle up to en...

Страница 27: ...23 Hypro Pump Information Hypro Pump Information...

Страница 28: ...24 Hypro Pump Information Hypro Pump Operation Maintanence Con t...

Страница 29: ...25 Hypro Pump Information...

Страница 30: ...26 Hypro Pump Information...

Страница 31: ...27 Hypro Pump Information...

Страница 32: ...28 Hypro Pump Information...

Страница 33: ...29 Remco Pump Information...

Страница 34: ...30 Remco Pump Information...

Отзывы: