19
Tip the sprayer on the back side and insert the tongue into
the mount tube and secure it with the clip pin.
Attach the boom mounts to the sprayer deck with the 5/16”
x ¾” hex head bolts.
Attach the boom to the boom mounts at the desired height
with the 3/8” x 2½” hex head bolts and pads.
Secure the supply hose over the hosebarb with the hose
clamp.
Tongue >
Clip Pin >
Mount Tube >
Figure D1
Tongue Mounting
Boom Mount Brackets >
Boom >
< Supply Hose
< Hosebarb
Sprayer Deck >
Figure D2
Boom Mounting
L&G Inspection & Setup
The pump is supplied with a red (+) and brown (-) wire,
and an in-line fuse.
Mount the toggle switch in a convenient location on the
tow vehicle. Attach the brown (-) wire to a ground source
using a quick splicer or a vinyl ring terminal. Cut the red
(+) wire, attach both ends to the toggle switch with the
female push-on terminals. Attach the loose end of the red
(+) wire to a power (+) source using a quick splicer or a
vinyl ring terminal.
Preparing Sprayer for Operation
Add about 5 gallons of water to the spray tank. Do not add
any chemical until the sprayer has been checked for proper
operation. Do not install spray tips in the nozzle bodies on
the boom until the lines have been flushed.
Open the ball valve located beside the pump.
Figure D3
Electrical Connections
Pump >
< Red (+) Wire
Brown (-) Wire
Toggle Switch >
Female Push-On >
Terminal
< Vinyl Ring Terminal
< Quick Splicers
< Fuse
Figure D4
Boom Ball Valve
< Open Boom
Ball Valve
Содержание Defender 3 Pt Sprayer
Страница 4: ......
Страница 27: ...23 Hypro Pump Information Hypro Pump Information...
Страница 28: ...24 Hypro Pump Information Hypro Pump Operation Maintanence Con t...
Страница 29: ...25 Hypro Pump Information...
Страница 30: ...26 Hypro Pump Information...
Страница 31: ...27 Hypro Pump Information...
Страница 32: ...28 Hypro Pump Information...
Страница 33: ...29 Remco Pump Information...
Страница 34: ...30 Remco Pump Information...