6
Defender Insp & Setup
Defender Inspection & Setup
Your Wylie “Defender” 3 Point Sprayer was manufactured
to the highest standards of quality. It is necessary though,
to check to make sure that nothing was damaged during
shipping. Check bolts and fasteners for tightness. Check
the pump and plumbing for any signs of damage.
”Defender” Sprayer Inspection & Setup
Your Wylie “Defender” sprayer was completely assembled
and should not need any additional assembly before use.
However, if the sprayer was motor freighted directly to you,
minor assembly will be required.
The control will need to be bolted to the control stand. The
bolts should be in the stand. The boomless nozzle bracket
(if equipped) was shipped bolted inside the frame. Unbolt
the bracket and reattach on the outside of the frame. The
boom should be attached to the sprayer frame by center
-
ing the center section on the frame and securing with the
bolts and pads as shown in Figure A2.
Attaching ”Defender” Sprayer to Tractor
Before attaching the sprayer to the tractor, determine the
category of your tractor hitch. The 50 and 100 gallon spray
-
ers are equipped with a Cat. I hitch, while the 200 gallon
sprayer is equipped with a Cat. II/III hitch. The category
of the tractor and sprayer hitch must be the same for the
sprayer to mount properly.
Back the tractor to the sprayer. Make sure that other people
are clear of the area.
Pin the lower lift arms of the tractor 3 point hitch to the lower
hitches of the sprayer. Pin the top link to the sprayer top
hitch. Adjust the top link, if necessary, to level the sprayer
when it is in the operating position.
Make sure the tractor engine is shut off before sliding the
pump coupler on the PTO shaft. The Hypro roller pumps
and CDS/John Blue diaphragm pump are designed to op
-
erate at 540 RPM. Mount the pump to the 540 RPM shaft
(usually a 1 3/8”, 6 spline shaft). If the pump is equipped
with a quick coupler, pull the coupler collar back as the
coupler is slid on the PTO shaft. Release the collar and slide
the pump until the coupler snaps into place on the shaft.
Secure the pump chain around the tractor drawbar to pre
-
vent the pump from spinning with PTO shaft.
Figure A1
Shipping Assembly
Do not stand between the sprayer and a moving tractor.
Doing so could cause serious injury or death.
Set tractor brake and place in park or shut off
engine before securing hitch pins.
Shut the tractor engine off before mounting the
pump to the PTO shaft. Failure to do so could
allow the PTO shaft to engage causing
serious injury or death.
Figure A2
Mounting Boom To Frame
Boomless >
Nozzle Bracket
< Control
Stand
Flat Fold Boom >
< Mounting Pad
Содержание Defender 3 Pt Sprayer
Страница 4: ......
Страница 27: ...23 Hypro Pump Information Hypro Pump Information...
Страница 28: ...24 Hypro Pump Information Hypro Pump Operation Maintanence Con t...
Страница 29: ...25 Hypro Pump Information...
Страница 30: ...26 Hypro Pump Information...
Страница 31: ...27 Hypro Pump Information...
Страница 32: ...28 Hypro Pump Information...
Страница 33: ...29 Remco Pump Information...
Страница 34: ...30 Remco Pump Information...