SECTION 8
CONNECTING EQUIPMENT TO THE
LIGHTNING DATA RECEIVER QUICK
REFERENCE GUIDE AND CHECKLIST
Check boxes after completing steps.
STEP 1
Remove the front cover from the LDR by taking off the four brass
thumbscrews. Handle the cover carefully and place it face down (circuit
board up) upon a soft surface.
STEP 2
Locate the 7 position screw-terminal block labeled J202 on the printed
circuit board. Make connections to the main and auxiliary relays
according to the contact assignments given below. The terminal block
contacts can accept wire up to 18 gauge. A 1/8 inch flat-bladed
screwdriver is required to secure wires in the terminal block.
J202 control connector contact assignments as viewed from the
component side of the printed circuit board with typical Siren System
wiring:
QPS & WAVE SYSTEM WIRING DIAGRAM
RELAY
MAIN RELAY K200
AUX RELAY K201
CONTACT
1
2
3
4
5
6
7
FUNCTION
NC
NO
C
NC
NO
C
GND
WAVE
SIREN
Orange
& White
Green &
White
Orange
Blue
QPS SIREN
Green
Red
Black
Black
NC
=
NORMALLY CLOSED
NO
=
NORMALLY OPEN
C
=
COMMON CONTACT
WAVE protective bond wire connections:
The Blue and Blue/White wire from the WAVE Transmitter is circuit and
chassis ground and it must be connected to contact 7 of J202 of the LDR.
QPS protective bond wire connections:
The black wire is circuit and chassis ground from the QPS Master Control
Transmitter and it must be made common with the circuit and chassis
ground (terminal 7 of J202) of the LDR as shown above.
Strike Guard Lightning Warning System
26
DEC 2013
Содержание Strike Guard
Страница 1: ...Strike Guard LIGHTNING WARNING SYSTEM USER S GUIDE Strike Guard Lightning Warning System 1 DEC 2013 ...
Страница 32: ...Strike Guard Lightning Warning System 32 DEC 2013 ...
Страница 33: ...Strike Guard Lightning Warning System 33 DEC 2013 ...
Страница 34: ...Strike Guard Lightning Warning System 34 DEC 2013 ...
Страница 35: ...Strike Guard Lightning Warning System 35 DEC 2013 ...
Страница 36: ...Strike Guard Lightning Warning System 36 DEC 2013 ...
Страница 37: ...Strike Guard Lightning Warning System 37 DEC 2013 ...