6. W202, AUX RELAY FUNCTION SELECT
The Auxiliary Relay allows for additional relay signaling or external device triggering
based on system failure or lightning conditions.
•
•
F
(FAIL) This setting actuates the auxiliary relay on Sensor Battery Low or
Sensor Test Fail, or No Communication conditions. The relay will not return
to a normal state until all Sensor-related failure conditions have cleared. Note
that FAIL selection will actuate on LDR power up (because No
Communication is received from the Sensor) and will be reset with the first
PASS SELF TEST message or other valid message from the Lightning
Sensor.
•
•
C
(CAUTION) This setting actuates the auxiliary relay on detection of any
lightning for the duration of the re-triggerable Caution Time Interval.
•O
•
A
(ALARM) Actuates on selection in W203. Setting this jumper to A or ALARM,
duplicates the main relay function in the auxiliary relay with the same time
interval as the main relay. (
FACTORY SETTING
).
G. CONNECTIONS TO THE CONTROL CONNECTOR
CONTROL CONNECTOR FOR CONTACT-CLOSURE SIGNALING OF EXTERNAL
EQUIPMENT
J202 control connector contact assignments as viewed from the component side of the
printed circuit board with typical QPS and WAVE Siren System wiring:
QPS & WAVE SYSTEM WIRING DIAGRAM
RELAY
MAIN RELAY K200
AUX RELAY K201
CONTACT
1
2
3
4
5
6
7
FUNCTION
NC
NO
C
NC
NO
C
GND
WAVE
SIREN
Orange
& White
Green &
White
Orange
Blue
QPS SIREN
Green
Red
Black
Black
NC
=
NORMALLY CLOSED
NO
=
NORMALLY OPEN
C
=
COMMON CONTACT
WAVE PROTECTIVE BOND WIRE CONNECTIONS
The Blue and Blue/White wire from the WAVE Transmitter is circuit and chassis ground
and it must be connected to contact 7 of J202 of the Lightning Data Receiver.
QPS PROTECTIVE BOND WIRE CONNECTIONS
The black wire is circuit and chassis ground from the QPS Master Control Transmitter
and it must be made common with the circuit and chassis ground (terminal 7 of J202) of
the LDR as shown above.
Strike Guard Lightning Warning System
18
DEC 2013
Содержание Strike Guard
Страница 1: ...Strike Guard LIGHTNING WARNING SYSTEM USER S GUIDE Strike Guard Lightning Warning System 1 DEC 2013 ...
Страница 32: ...Strike Guard Lightning Warning System 32 DEC 2013 ...
Страница 33: ...Strike Guard Lightning Warning System 33 DEC 2013 ...
Страница 34: ...Strike Guard Lightning Warning System 34 DEC 2013 ...
Страница 35: ...Strike Guard Lightning Warning System 35 DEC 2013 ...
Страница 36: ...Strike Guard Lightning Warning System 36 DEC 2013 ...
Страница 37: ...Strike Guard Lightning Warning System 37 DEC 2013 ...