Interface Utilities Sub-menu
– this sub-menu allows you to define the remote control interface [USB, RS485 or
TCP/IP] to be used for controlling the WS-P48 :
UTILITY MENU
-- Interface Utilities --
.
From “Interface Utilities”, press “ENTER” to access the Interface Setup.
−
Interface Setup:
this screen allows you to choose the remote control protocol for the WS-P48.
INTERFACE UTILITY
-- Interface Setup --
By pressing “ENTER” and then using the PM2 or PM3 encoders you can choose between the three possible
interfaces (USB, RS4854 or TCP/IP) for the WS-P48.
Pressing ENTER on a selected source will make an asterisk appear to the right of the description on the LCD
as in the following example which shows the selected interface as USB.
Interface Setup
Source: USB *
If selected the RS485 option, using the encoders PM2/PM3 and pressing “Enter”, the possibility of setting the
ID Number characterising the Unit during a Multi Units connection through RS485, is given turning the PM1
counter clockwise and adjusting the ID Num to assign to the Unit, from 01 up to 32.
Interface Setup
Remote ID Num = 01 *
Security Sub-menu
– this sub-menu allows the User to set the parameters shown, lock the
WS-P48 and set a Password therefore limiting the unit's functions and controls to those who have access to the
appropriate Password.
UTILITY MENU
-- Security Utilities --
Press ENTER and then use the NAV/PM1 to scroll between options.
−
Show Parameter:
Pressing ENTER from the above menu will access the “Show Parameter” Sub Menu
SECURITY UTILITY
-- Show Parameter --
Press ENTER again and use the PM2 or PM3 encoders to scroll between the “be shown” and “not be shown”
options. An asterisk will highlight which option is selected.
Choosing the “be shown” option means that once the unit is locked, you cannot access parameter editing
features, but they will be displayed on the LCD screen.
Choosing the “not be shown” option means that once the unit is locked, the parameters will not be shown at all.
With this option, when trying to access a parameter, the following screen message will appear:
Parameter will
not be shown *