45
Other Settings
OTHER SETTINGS
PREAMBLE -------------------------
1
POSTAMBLE ------------------------ 2
CHARACTERS ----------------------- 3
EOF STRING -------------------------
4
DONE/EXIT ----------------------------- 0
CHANGE SETTING #: _
Preamble and Postamble
The
Preamble
and Postamble apply to data entered in NON-PORTABLE MODE only.
Upload Prefixes
are used in programs for portable
data collection.
o
Preambles
are user-defined data that is transmitted at the beginning of data (bar code or keyed) that is entered in the TriCoder in
NON PORTABLE mode. For example, if you set a preamble of
@@
and scanned bar code data of
12345
,
@@12345
would be
transmitted to the computer.
o
Postambles
are user-defined data that is transmitted at the end of data (bar code or keyed) that is entered in the TriCoder in NON
PORTABLE mode. For example, if you set a preamble of
@@
and scanned bar code data of
12345
,
12345@@
would be
transmitted to the computer.
o
By default, the TriCoder has no preambles or postambles configured. Preambles and Postambles can each contain up to 15
characters scanned from the bar coded FULL ASCII Menu.
To set a preamble or postamble:
1.
Press the
5
key at the
Main Menu
(opening screen)
2.
Press the
7
key at the
TRICODER SETUP
screen
3.
Select
1
for
Preamble
or
2
for
Postamble
.
4.
Enter keys from the keypad or Scan any other desired characters (up to 15) from the FULL ASCII Menu (available on
the Utilities CD-ROM or from our website www.barcodehq.com/downloads.html).
5.
Press the
ENTER
key on the TriCoder keypad to store the characters you want.
6.
To clear the
Preamble
or
Postamble
and return to the default (no Preambles or Postambles defined), key
CLEAR
at step #4, then continue with your setup.
You can use the
Preamble
or
Postamble
to trim characters from the data you are entering into the TriCoder in NON
PORTABLE mode.
The Upload Prefix and Suffix is used to trim data in portable mode (data collection).
You can trim from 1-
15 characters from the data by creating a preamble or postamble of:
~
x
where
~ is ASCII 126 and
x
is a single hex digit 1-F (corresponding to 1-15). Data that is shorter than the trim amount are
transmitted without trimming.
Preambles
trim data from the front;
Postambles
trim characters from the end.
Here are some examples, with and without trimming included:
Data Scanned
Preamble Value
Data Transmitted
123
XYZ
XYZ123
12345678
~3XYZ
XYZ45678
12345678
~9
12345678
12345678901
~A
1
123456
~5
6
Preamble affects leading (high order) characters
Data Scanned
Postamble Value
Data Transmitted
123
XYZ
123XYZ
12345678
~3XYZ
12345XYZ
12345678
~9
12345678
12345678901
~A
1
123456
~5
1
Postamble affects trailing (low order) characters