![Worth Data 5000 TriCoder s Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/worth-data/5000-tricoder-s/5000-tricoder-s_owners-manual_998080039.webp)
38
Terminator Character
I/O SETTINGS
HOST -------------
HID KEYBOARD
1
TERMINATOR CHARACTER -
CR
2
SINGLE CYCLE UPLOAD
OFF
3
BAUD RATE ----------------------
9600
4
PARITY ---------------------------
NONE
5
DATA BITS -----------------------
8
BITS
6
USB ENUMERATION DELAY:
0
7
USB HID SPEED ----------------
FAST
8
USB HID ALT OUTPUT ------
OFF
9
DONE/EXIT ------------------------------------
0
CHANGE SETTING #: _
o
The
Terminator Character
is the character sent at the end of each data entry in NON PORTABLE mode and at the end of
each field when uploading after data collection (Portable use). Your application will determine what Terminator Character
(if any) you use. Options for Terminator Character Are: CR, TAB, CR/LF, NONE. Pressing the Number 2 on the TriCoder
keypad will cycle through those options. In HID Keyboard,
CR
is the default. For Serial Interface,
CR/LF
is the default.
Single Cycle Upload
I/O SETTINGS
HOST ----------------
HID KEYBOARD
1
TERMINATOR CHARACTER -
CR
2
SINGLE CYCLE UPLOAD
OFF
3
BAUD RATE ----------------------
9600
4
PARITY ---------------------------
NONE
5
DATA BITS -----------------------
8
BITS
6
USB ENUMERATION DELAY:
0
7
USB HID SPEED ----------------
FAST
8
USB HID ALT OUTPUT ------
OFF
9
DONE/EXIT ------------------------------------
0
CHANGE SETTING #: _
o
Single Cycle Upload
allows the TriCoder to upload one field at a time to the host, controlled by the pressing of any key
(except
) on the TriCoder each time the operator wants to transmit a field.
Single Cycle Upload
is set to OFF by
default, but when set to ON it can be used to test complex upload prefix and suffix sequences. This is typically used when a
TriCoder is used in
HID KEYBOARD
mode and you are uploading directly into an application.
Single Cycle Upload
allows you to test key sequences and delays before you collect a lot of data and try an upload. Pressing
terminates the
upload session.
Baud Rate
Set the
Baud Rate
to match your serial port settings on the computer you will be uploading to.
I/O SETTINGS
HOST -----------------------------
SERIAL
1
TERMINATOR CHARACTER -
CR
2
SINGLE CYCLE UPLOAD
OFF
3
BAUD RATE ----------------------
9600
4
PARITY ---------------------------
NONE
5
DATA BITS -----------------------
8
BITS
6
PROTOCOL -----------------------
NONE
7
DONE/EXIT ------------------------------------
0
CHANGE SETTING #: _
o
To change the
Baud Rate
you can cycle through the options by pressing the
4
key on the TriCoder keypad. Choices are:
2400, 4800,
9600
, 19200, 38400, 57600, or 115200