2. ADVANCED SETTINGS AND ADMINISTRATOR MODE
Total Number of Inspec ons
– The total number of measurements from launch the automa c inspec on.
Number of OK Inspec ons
– The number of inspec ons with the correct result (all rows in a table is green).
Number of NOK Inspec ons
– The number of inspec ons with the wrong result (at least one row in the
table is red).
Number of Log Posi on
– Displays how many logs can be wri en on disc before filling.
Log Full Icon
– Indicates a disc is full. If lights green with word Enough, there is enough space on disc. If
lights red with word Full, it is necessary archive logs and delete from disc.
Other bu ons are used to select what informa on will be displayed in the middle of the Status bar under the
window with the thermographic video signal.
Resolu on and Zoom
– Displays resolu on of camera and the current zoom of the video signal in window.
Resolu on and FPS
– Displays resolu on and the current frame rate of camera.
Camera Temperature
– Displays current temperature inside the camera. The period of updates to set the
right of temperature.
Graph Visualiza on
In this menu, you select what type of chart to be displayed in the operator mode.
Discon nuous Chart
– Displays waveforms of sta s cs in each ROI during the last measurement.
Con nuous Chart
– Displays waveforms of sta s cs con nuous in me (even outside measurements).
Last Result Chart
- Displays waveforms of sta s cs in each ROI during the last measurement over me.
Temperature Profiles
– Shows the temperature profiles of each ROI in me.
Graph Pale e
– Sets display pallets for handling graph (zoom and shi chart)
Graph Legend
– Sets the display of legend with individual ROI.
Time Window Length
– Sets the length of the window which displays data in me. This se ng is available
only for
Con nuous Chart
.
Sampling Interval
– Sets the speed of data recovery in
Con nuous Chart
,
Con nuous Indicator
,
Current
Value
in the table with defini on of measurement areas and
Pale e
of temperature range.
Numeric Visualiza on
In this menu, set the proper es of numerical outputs the measured values in the operator mode.
Discon nuous Indicator
– Displays only the resul ng value of sta s cs of measurement in the selected ROI.
Con nuous Indicator
– Con nuously displays the value of sta s cs in the selected ROI.
Num. of Outputs
– Specifies the number of numerical outputs (1-4).
Select ROI
– A choice that ROI will be displayed on the numerical output.
Create Envelope
– If this bu on is ac ve, system is crea ng envelope from all measurement un l the bu on
is again inac ve. For using envelope like a evalua on criterion, you have to check this op on in
Edi ng
Dialog for ROI
(see Figure 2.21).
External Temperature
– Allows you to send star ng temperature of measured object for precise adjustment
of ROI
Criterion Value
.
E-mail and Web
[email protected]
www.workswell.eu
Mobile:
+420 725 877 063
ID:
Reg. No.: 29048575
VAT No.: CZ29048575
Headquarters
Libocka 653/51b
Prague, Czech Republic
Revision 2.6 EN, 14
th
Feb, 2019
All pictures are only for illustra on.
Real values may vary.