INSTALLATION
Greenstar Ri Compact 6 720 646 610 (2013/12)
25
2. Refit to the terminal, ensuring that the clips (1 & 2) are engaged and
secure.
3. Loosen screws (3) and rotate the entire outlet assembly to redirect
the plume. Tighten screws (3) to secure in the required position.
Fig. 41 Plume redirection
Fig. 42 Plume distance to opening
4.6
ELECTRICAL
ELECTRICAL - STANDARD 230V WIRING CENTRE INSTALLATIONS
▶ The mains electrical supply to the boiler and system wiring centre
must be common, and through either a fused double pole isolator or a
fused three pin plug and unswitched socket.
▶ The isolator/socket, where practicable, should be situated next to the
boiler.
▶ The isolator must have a minimum of 3mm contact separation in both
poles.
▶ Any system connected to the boiler must not have a separate
electrical supply.
▶ External fuse rating 3A.
▶ Route the 230 V mains power cable, from the control box, to the
mains isolator next to the boiler.
ELECTRICAL - GREENSTAR WIRING CENTRE (OPTIONAL
ACCESSORY)
The additional following information applies:
▶ The mains electrical supply to the boiler and system wiring centre
should where practicable be common, and through either a fused
double pole isolator or a fused three pin plug and unswitched socket.
▶ If separate isolators are used refer to the Greenstar Wiring Centre
Installation Commissioning & Servicing Instructions for further
information
ACCESS TO ELECTRICAL CONNECTIONS
1. Refer to fig. 43 and remove the screws in the installer access cover.
2. Lift the “Installer access cover”.
3. Remove the cover.
The flue terminal outlet has built-in stops to limit rotation
for horizontal flues to allow condensate to run back into
the boiler for safe disposal. Do not attempt to force
beyond the limit stops.
NOTICE:
Outlet position
▶ The flue terminal outlet position must follow those
stated in the relevant appliance instruction manual.
When redirecting the flue discharge the outlet
terminal must be at least 1500mm from any opening
in the direction of the discharge to prevent
combustion products from entering the building.
1
2
1.
3.
2.
3 1
±80°
180°
1
3
4
2
1
Opening in building
2
Flue discharge
3
Plume deflector
4
Minimum 1500mm from an opening in the building
Table 8 Key to figure 42
CAUTION:
Mains electrical supply
▶ Isolate the mains electrical supply before starting any
work and observe all relevant safety precautions.
NOTICE:
The boiler is fitted with a mains power cable.
▶ Should this not be required it can be removed and
replaced with a cable suitable to the installation.
The electrical connector from the PCB must be
re-used. A replacement grommet is provided in the
hardware/literature pack but must be cut to suit the
cable diameter when fitting.