FAULT FINDING AND DIAGNOSIS
Greenstar Ri Compact 6 720 646 610 (2013/12)
49
7.1.2 GROUP 2 FAULT CODES
Fig. 106 Group 2 flash sequences
Flash
sequence
Type of fault
Fault
Possible solutions/check
Light OFF
No boiler demand - boiler is OK
Light ON
Heating demand on boiler- boiler is OK
Group 2 Flashing codes
6
Locking
Sensor test failed
On power up all safety sensors are checked, the
check failed.
Reset the boiler by turning the control knob anti-
clockwise to the reset position.
7
Locking
Safety temperature too high
The main heat exchanger has overheated.
Maximum temperature 105°C.
Reset the boiler by turning the control knob anti-
clockwise to the reset position.
8 Blocking
MAX safety thermostat activated
Flue gas thermostat overheat
9
Locking
Return temperature too high
Boiler overheat.
Reset the boiler by turning the control knob anti-
clockwise to the reset position.
10
Locking
Flow temperature too high -
Supply sensor exceeded 110°C
Primary flow sensor overheated.
Reset the boiler by turning the control knob anti-
clockwise to the reset position.