PRE-INSTALLATION
Greenstar Ri Compact 6 720 646 610 (2013/12)
13
In situations where there are likely to be extremes of temperature or
exposure, the use of a proprietary trace-heating system for external pipe
work, incorporating an external frost thermostat, should be considered.
If such a system is used, the requirement to use 32mm pipe does not
apply. However, all other guidance above and the instructions for the
trace heating system, should be closely followed.
Fig. 9
Condensate pump to external disposal
Fig. 10 Soak away
3.5
BOILER LOCATION AND CLEARANCES
3.5.1 INSTALLATION
This boiler is only suitable for installing internally within a property at a
suitable location onto a fixed, rigid surface at least the same size as the
boiler and capable of supporting the boiler weight.
3.5.2
INSTALLATION AND SERVICING CLEARANCES
Figure 11 shows the minimum space required to install and service the
boiler in a compartment.
Fig. 11 Unventilated compartment
[*]
Minimum clearance to removable door
[**]
Minimum clearance required for servicing
[***]
Height for either 60/100 flue or 80/125 flue
3.5.3
COMPARTMENTS:
Follow the requirements of BS6798 and BS5440 Part 2 and note:
• Minimum clearances must be maintained.
• An access door is required to install, service and maintain the boiler
and any ancillary equipment.
• If fitting the boiler into an airing cupboard use a non-combustible
material to separate the boiler from the airing space.
The material can be perforated up to a maximum hole size of 13mm.
3.5.4
BATHROOMS
The appliance may be installed outside the shaded area, and in zone 2.
Additional RCD (Residual Current Device) protection may be required.
Refer to the latest IEE wiring regulations.
Fig. 12 Bathroom installations
Minimum hole size for the condensate soak away must be
400mm deep by 300mmØ .
NOTICE:
Unheated internal areas.
▶ Internal pipe runs in unheated areas such as lofts,
basements and garages should be treated as external
runs and consideration should be given to using a
CondenseSure siphon.
NOTICE:
No surface protection is required against heat transfer
from the boiler
25mm min.
14
13
1
7
6720644744-12.2Wo
*
13
14
10
500mm min.
25mm min.
400mm
min.
1
12
11
9
6720644744-1
1.2W
o
9
10
*
6720646610-62.1W
o
960/1000mm
870mm
290mm
400mm
170/210mm***
600mm**
5mm
5mm
200mm
20mm*
6720646608-124.3Wo
2*
Radius 600mm
1
2
1
2
2
1
600mm
600mm
600mm
2250mm
2250mm
2*