To avoid electrocution or fire, any maintenance or repair to electrical system should be done only
by qualified electricians using genuine replacement parts.
WARNING
3.3 ELECTRICAL CONNECTION
- Electrical installation should be carried out by competent, qualified personnel.
- The mains connection should be made using the terminal box.
- Replacement of the power supply cable should only be done by a qualified electrician.
- Connect the main leads to a standard 400V±10% for TS315 and 230V±10% for TS315 (50Hz+1%Hz) electrical
supply which has protection devices of under-voltage, over-voltage, over-current as well as a residual current device
(RCD) which maximum residual current rated at 0.03A, the main connection must have maximum 20A time-lag fuse for
TS315 and 10A for TS315. The test specified in 18.2 of EN 60204-1:2006 should be performed by end user after final
installation.
3. SPECIFICATIONS
3.1 MAIN COMPONENTS
3.2 TECHNICAL SPECIFICATION
-6-
SPECIFICATION
Motor Voltage
230V/50Hz / 3~400V/50Hz
Main motor power
2.5kW,S1
Scoring motor power
550W,S1
Main blade diameter
315mm
Main blade speed
4500rpm
Scoring blade diameter
120mm
Scoring blade speed
8000rpm
Blade tilt
0~45°
Main table size
800x530mm
Right extension table size
800x470mm/800x820mm
Max.rip capacity
900mm/1250mm
Max.depth of cut
95mm@90°,67mm@45°
Sliding table size
1200x310mm/1600x310mm
Square sliding table size
600x460mm
1
2
3
4
5
6
12
7
8
9
10
11
1 - Right extension table
2 - Main table
3 - Blade guard assembly
4 - Blade
5 - Rear extension table
10 - Slide
11 - Material baffle composition
12 - Sub-slide table(optional)
6 - Feet
7 - Sub-slide
8 - saw blade deflects handwheel
9 - Composition