16 - TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Vacuum doesn’t turn on
The switch button of the
vacuum unit is OFF
Press the button
The micro line cable is not
connected
See p. 21,22
Control Panel alert is on
See Control Panel manual
Faulty electrical/electronic
parts
Call the Technical Service
There is no air suction from just
one vacuum inlet
The electric contacts are
interrupted or the microswitch
of the suction socket is out
of order
Call the Technical Service
The air suction is weak
More than one vacuum inlet is
being used at the same time
Use only one vacuum inlet at
the same time
The fl exible hose or the
cleaning accessories are
broken
Check that the fl exible hose
and the accessories are not
damaged (change them if
necessary)
The sealing gasket of the dust
bin is damaged
Check sealing gasket integrity
There is a clogging in the
vacuum inlet of the pipe
network
Call the Technical Service
The air exhaust outlet is
blocked
Call the Technical Service