Instructions manual NOVA 2 vacuum unit
1/04/17 Rev:1.0.0
16
8.3 Positioning of the vacuum cleaning unit
For a correct use and to facilitate maintenance it is advisable to keep a minimum distance of 60 cm on
three sides around the appliance (excluding the side on which it is fi xed to the wall).
2
Trace the drilling position using the template provided
(drilling template); if this has already been done, proceed to
the next step.
Drill the holes
8.4 Fixing the vacuum cleaner to the wall
The vacuum cleaner must be securely and permanently fi xed to a solid wall using the bracket provided
and the suitable wall anchors or plugs taking into account that the total weight to be supported can be
seven/eight times that of the system itself.
The system should be positioned high enough off the ground to allow the dust collection bin to be
emptied and the fi lter to be replaced in a simple way.
To do this follow the instructions detailed below:
Height from the ground is detailed in the table below:
500
1
Nova
Model
Article
Nova 2
770305
Measurement X (min.)
mm
500