8.6 Instructions for Woodco systems installation

Pipe network 
Pipe lengths, allowed between the different components of the vacuum unit, are indicative and pro-
visional.
To do Woodco systems it is necessary to use strong and long-lasting installation material, available 
in antistatic zync-coated pipes Ø 50 mm, or PVC installation material. 
All connections must be watertight, in order to grant the maximum performance . 
It is better to realize the pipe network in a straight line, because with many direction changes it is 
necessary to realize a shorter pipe network.
Avoid networks with positive or negative traps.
For some connections it is possible to use spiral pipe, in antistatic plastic material, with smooth 
internal walls. Radius of curvature for installation made with fl exible hose cannot be under 30 cm.
It is better to reduce to the minimum sections realized in fl exible hose, to optimize installation per-
formances. All pipes must be fi xed to walls or strong supports every 150 cm.  

Horizontal sections 

must be made with spirit level, while vertical sections cannot be over 3,5 meters.

In case of connection between rigid steel pipes and fl exible pipes, the spiral inside the fl exible hose 
must be connected to the steel pipe, to grant antistatic properties.
To avoid electrostatic charges, pipe network must be grounded, in accordance with current rules.

Warning
We recommend using only original pipes, connections and accessories as they have been realized 
on this purpose.
Before installing and using Woodco system, we recommend to read this manual carefully and, in 
case of doubts, please contact qualifi ed person.

Construction and installation of systems must be made according to safety rules related 
to the place they are installed in.

WARNING: the system installation must be

made by qualifi ed personnel only.

Fuel

MAX m 25

MAX m 5

Ø

 50 mm

Dusts

Air

Air vent

Содержание Nova 2

Страница 1: ...2 TECHNICAL MANUAL NOVA 2 VACUUM UNIT...

Страница 2: ......

Страница 3: ...RIZED USE OF THE VACUUM CLEANER 13 6 UNAUTHORIZED USE OF THE VACUUM CLEANER 13 7 EQUIPMENT AND ACCESSORIES 14 8 INSTALLATION 15 8 1 Preliminary operations 15 8 2 Place of installation 15 8 3 Positioni...

Страница 4: ...The system has been manufactured with top quality materials and with particular care paid to reduction of injury risk as much as possible Therefore we have written this manual in order to provide ade...

Страница 5: ...ent correctly in order to obtain the best performan ce with optimal working and safety conditions It is strictly forbidden to reproduce copy or disclose any part of this document by any means without...

Страница 6: ...ev 1 0 0 6 2 TECHNICAL DATA Nova 2 G H F A B C L D E Sound absorbing dome Motor group Body Filter cartridge Bin dust container 1 2 3 4 5 Power supply cable Switch on signal cable Micro line 6 7 Air ve...

Страница 7: ...6 Inlets power V dc 12 Maximum air flow m3 h 234 Filtering surface cm2 6700 Dust bin capacity l 18 Air exhaust YES Silencer 50 mm YES Weight kg 7 Size A mm 160 Size B mm 110 Size C mm 210 Size D mm 39...

Страница 8: ...technical characteristics are as follows Plastic material cylindrical body Large capacity dust container 18 l Soundproofed motor compartment max sound level below 70 dBA Motor rotor group equipped wi...

Страница 9: ...v 1 0 0 3 1 Set Nova 2 Filter knob Filter cartridge Motor Protection grid Lower motor gasket Upper motor gasket Fixing plate 2 3 4 5 Body Bin gasket support Handle and closing hook Dust container 12 1...

Страница 10: ...y persons including children with reduced psychic sensory or mental capacities or by persons with no experience nor knowledge of the system unless they are under the guidance or instructed in the use...

Страница 11: ...s which comply with the restrictions established by the health and environment protection re gulations in force and do not contain SVHC classified substances Substance of Very High Concern in complian...

Страница 12: ...replace the screws used for the design and manufacture the appliances with screws with feature different characteristics The Manufacturer will immediately suspend the product guarantee in case of mac...

Страница 13: ...explo sion and therefore it is forbidden to vacuum clean materials with high explosion risk gunpowder or materials which are individually inert but that once collected and mixed in the dust bin could...

Страница 14: ...g as follows 1 N 1 vacuum unit 2 N 1 metal bracket to fix the unit to the wall 3 N 2 rubber sleeves for the connection to the vacuum pipe network 4 N 4 metal clamps to fix the sleeves 5 N 1 installati...

Страница 15: ...that the equipment and the kit have been exactly and completely delivered If any damage or irregularity is found or if any accessory is missing do not install the appliance and contact your Retailer 8...

Страница 16: ...rill the holes 8 4 Fixing the vacuum cleaner to the wall The vacuum cleaner must be securely and permanently fixed to a solid wall using the bracket provided and the suitable wall anchors or plugs tak...

Страница 17: ...cleaner identified with B in the picture to the suction pipe from the piping network 2 Using the sleeve connect the venting air coupling of the central vacuum cleaner identified with C 3 Place the sil...

Страница 18: ...er 30 cm It is better to reduce to the minimum sections realized in flexible hose to optimize installation per formances All pipes must be fixed to walls or strong supports every 150 cm Horizontal sec...

Страница 19: ...a nual Insert the plug of the power supply cable from the central system in the electric inlet Check that the electrical wiring of the house has been set up in compliance with the electrical regulatio...

Страница 20: ...This is made by an electric contact inside the electric board of the Control Panel or inside the vacuum inlet that lights up the motor of the vacuum unit Routine maintenance involves the dust bin to...

Страница 21: ...us mechanical damages BEFORE CARRYING OUT ANY MAINTENANCE OPERATION IT IS MANDATORY TO UNPLUG THE POWER SUPPLY CABLE FROM THE POWER SUPPLY INLET PROTECTIVE MASK AND GLOVES MUST ABSOLUTELY BE WORN Main...

Страница 22: ...cone 2 Remove the dust bin 1 Empty the dust bin 3 Put the conveyor cone back in position 4 Reassemble the dust bin inside its housing under the vacuum unit lock the closing handles Switch the suction...

Страница 23: ...that deposit between the folds N B Check the filter surface is not cut If this is the case the filter cartridge should not be used again and should be defini tely replaced ATTENTION ALWAYS VERIFY THAT...

Страница 24: ...le for any eventual damage to persons and or objects due to such interventions 12 2 Recommended spare parts It is advisable to order in time those spare parts which need to be changed more often In or...

Страница 25: ...vity wall preferably made of solid bricks Avoid fixing the system to an internal dividing wall it is better to fix it to an external perimeter wall You can also use sound absorbing materials on the tw...

Страница 26: ...ric contacts are interrupted or the microswitch of the suction socket is out of order Call the Technical Service The air suction is weak More than one vacuum inlet is being used at the same time Use o...

Страница 27: ...se accident negligence modification repair alteration or not authorized disassembly 2 maintenance operations use not in accordance with the product instructions or connection to wrong electrical suppl...

Страница 28: ...Instructions manual NOVA 2 vacuum unit 1 04 17 Rev 1 0 0 28...

Страница 29: ...29 English 1 04 17 Rev 1 0 0 APPENDIX A EXAMPLE OF INSTALLATION WITH NOVA...

Страница 30: ...30 INSTALLATION PLAN WITH SINGLE PIPE AND SCREW EXTRACTING CASE 1 2 3 4 5 6 7 8 1 Nova 2 vacuum unit art 770305 2 Control Panel Drive art 770308 3 Dispenser art 770306 4 Boiler with integrated tank 5...

Страница 31: ...WITH SINGLE PIPE AND VERTICAL EXTRACTOR 1 2 3 4 5 6 7 8 1 Nova 2 vacuum unit art 770305 2 Control Panel Drive art 770308 3 Dispenser art 770306 4 Boiler with integrated tank 5 6 7 silencer 8 Air vent...

Страница 32: ...tions manual NOVA 2 vacuum unit 1 04 17 Rev 1 0 0 32 Example of automatic feed system Woodco 1 Central vacuum unit 2 Control panel 3 fuel dispenser 4 stock tank 5 air vent OUT C C A P A P A C A A C 1...

Страница 33: ...1 04 17 Rev 1 0 0 33 English NOTES...

Страница 34: ...Instructions manual NOVA 2 vacuum unit 1 04 17 Rev 1 0 0 34 NOTES...

Страница 35: ......

Страница 36: ...NOVA 2 VACUUM UNIT F09200235 03 declan woodco energy com www woodco energy com...

Отзывы: