16
48D0139
19
CHECKING GAS PRESSURE
The appliance and its main gas valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas supply
piping system by closing its equipment shutoff valve during any pressure testing of the gas supply pipmg system at test
pressures equal or less than 1/2 psi (3.5 kPa).
CHECKING GAS PRESSURE
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install the
appliance. Contact your dealer immediately.
1
/
2
" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a solution of 50/50 water and
soap or a gas sniffer.
4.
Figure
13
.
After taking pressure reading, be sure and turn
captured screw clockwise firmly to reseal. Do not over
torque. Check test points for gas leaks.
Figure
13
- Gas Pressure Check at Gas Valve
Do not use open flame to check for gas leaks.
WARNING
Outlet Pressure Tap
Pilot Adjustment
Inlet Pressure Tap
2. To ease installation, a
30" (mm)
flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach
To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
See
Содержание DVI 750 (N
Страница 31: ...REPLACEMENT PARTS 8 Continued on Next Page 31 10 17 5 16 4 7 9 3 11 20 18 15 19 ...
Страница 32: ...REPLACEMENT PARTS Continued on Next Page 32 31 Log 1 Log 2 Log 3 Log 4 Log 5 Log 6 Log 7 ...
Страница 33: ...REPLACEMENT PARTS 8 5 7 4 6 33 1 2 7 4 12 3 21 22 23 ...
Страница 38: ...127 6 ...
Страница 39: ...127 6 ...