the Facade ready Fire Deck features cement board already installed on the front surfaces of the oven�
ANY MATERIALS
AFFIXED TO THE CEMENT BOARD MUST BE NONCOMBUSTIBLE.
The hatched area represents
surfaces of the oven that are
covered with cement board at the
factory. All parts of the oven which
are meant to be left exposed are
not hatched (see previous page).
A 1-inch wide stainless steel lip
is provided, around the doorway
opening and around the air intake
vent. This is provided so that
the noncombustible, sanitation
approved materials used to cover
the cement board can be neatly
terminated at these points.
Total thickness of facade materials,
including the cement board, should
not exceed 1-inch in thickness in area
above the door to allow removal of door
system components for service.
OVEN
CEMENT BO
ARD
1-inch stainless steel
perimeter lip
Tile or other noncombustible,
sanitation approved facade
material (supplied by others).
12
An ongoing program of product improvement may require us to change
specifications without notice.
FD-6045, Revised October 2013
or visit
woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
FACADE-READY OvENS
FD-6045 Fire Deck Oven
installation and Operation manual