1.
the Wood Stone Fire Deck oven must have a
minimum 1-inch clearance to combustibles from all sides, and 24-inch
clearance to combustibles from the top� if building materials will contact the oven, they must be completely non-
combustible� please note that standard Drywall (or Sheetrock) is considered a combustible� When non-combustible
building materials contact the body of the oven, the respective clearances are transferred to those non-combustibles�
2.
any facade 6 inches to either side of the oven doorway or above, must be constructed of non-combustible
building materials
�
3.
For use on non-combustible floors (installér sur un plancher incombustible seulement)� the non-combustible floor
surface should extend 36 inches out in front of the oven, and extend 30 inches to either side of the oven doorway�
1-inch minimum
side clearance
to combustible
construction
non-combustible
floor, 36" in front
and 30" to either
side of oven
doorway
maintain 24-inch
clearance from
top of the oven
TO REDUCE THE RISK OF FIRE, FOLLOW THESE INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED
FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF
UTMOST IMPORTANCE THAT THIS OVEN BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
!
WARNING:
installation and servicing of this product could expose you to glasswool/ceramic fibers
as well as calcium silicate dust�
ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN
INSTALLING OR SERVICING THIS APPLIANCE.
please read this entire manual before you install
the oven� Failure to follow instructions may result in property damage, bodily injury or even death�
contact your local building or fire officials about restrictions and installation inspection in your area�
!
WARNING:
Do not pack required air spaces (clearance) with insulation or other material� When
non-combustible building materials contact the body of the oven, the clearances to combustibles are
transferred to those non-combustibles�
10
An ongoing program of product improvement may require us to change
specifications without notice.
FD-6045, Revised October 2013
or visit
woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
INSTALLATION CLEARANCES
FD-6045 Fire Deck Oven