Maintenance & Alignment
Troubleshooting
3
3-9
PGdoc031914
Maintenance & Alignment
My pump does not turn on.
Improper wiring.
Check wiring per schematic.
Bad circuit board.
Ensure DS7 LED lights on circuit
board while trying to run. Ensure
24V signal to circuit board. Replace
circuit board.
Bad relay.
Ensure relay actuates. Replace
relay.
Bad pump.
Replace pump.
My end of cycle buzzer does
not turn on.
Bad buzzer.
Replace buzzer.
Bad circuit board.
Ensure DS9 LED lights when the
buzzer should be on. Ensure DS2
LED is lighted at all times. Replace
circuit board.
Bad PLC control.
Check the buzzer time setting and
ensure the buzzer is activated in the
settings. Replace PLC control.
Improper wiring.
Check wiring. Ensure 24V signal to
circuit board.
I keep getting "Index Time-
out" error.
Improper wiring.
Check wiring to the proximity sen-
sor. Ensure 24V to HMI while sensor
is active.
Bad PLC control.
Check control index time settings.
Run control sensor diagnostic.
Replace PLC control.
Bad sensor.
Check for damaged sensor. Ensure
sensor is in close proximity to index
cam. Replace sensor.
I keep getting "Index Fault"
error.
Bad cam index motor.
Replace motor.
Bad PLC control.
Check/Adjust the over-current set-
ting in the control.
Mechanical obstruction.
Check for obstructions. Ensure
smooth operation.
My index motor is turning the
wrong direction.
Improper wiring.
Interchange red and black leads to
cam index motor.
My grind motor is turning the
wrong direction.
Improper wiring.
Interchange internal leads to grind
motor. See motor nameplate for
detailed information.
PROBLEM
POSSIBLE CAUSE
SOLUTION