Setup & Operation
Operation
Setup & Operation
PGdoc031914
2-14
2
See Figure 2-13.
The depth and index adjustment knobs can be used to achieve the
proper grind of the tooth. Turn the index adjustment knob in toward the other knob to
move the tooth away from the grinding wheel. Turn the index adjustment knob away from
the other knob to move the tooth toward the grinding wheel. Turn the depth adjustment
knob clockwise to lower the grinding wheel toward the blade. Turn the depth adjustment
knob counterclockwise to raise the grinding wheel away from the blade.
NOTE:
The control will remain in this setup mode for two
minutes while you make the index/back grind adjustments.
If the cycle is not initiated within two minutes, the control will
timeout to the mode select menu.
After the index and depth grind adjustments are made, turn the feed rate up to grind the
next tooth. Adjust the depth and index grind as necessary using the adjustment knobs
until the desired amount of material is removed during grinding.
NOTE
: If a heavy grind is required, it is best to grind the
blade lightly twice than try to remove all the material in one
pass.
Once the grinder is adjusted and grinds a tooth as desired, press the START button again
to start the cycle. This will start the oil pump and begin counting the quantity of teeth to
grind during the cycle. Adjust the oil flow by opening or closing the valve on the grinder
head.
FIG. 2-13
Depth Adjustment Knob
Index Adjustment Knob
PG0005-10