MAINTENANCE
Safety Devices Inspection
MAINTENANCE
15doc042320
6-14
6
Try to start the motor without pressing the safety button. The moulder motor should remain
stopped.
Press and hold the green safety button. The moulder motor should remain stopped.
3. Inspection of the control circuits with the E-STOP button pressed
Press and hold the green safety button;
Turn on the moulder motor;
Press the E-STOP button located on the left side of the control box. The moulder motor
should be stopped.
With the E-STOP button pressed, try to move the moulder head up and down using the
up/down system button and forward/backward using the power feed switch. Both systems
should not start.
4. Cutter housing cover safety switch and its circuit inspection
Press and hold the green safety button;
Turn on the cutter motor;
Open the cutter housing cover;
The cutter motor should be stopped;
Try to start the motor. The motor should remain stopped.
Close the cutter housing cover;
The cutter motor should remain stopped until it is restarted with the START button.
Содержание MP100 E5S