SETWORKS OPERATION
Memory Buttons (A, B, C, D, E)
SETWORKS OPERATION
EGdoc042320
5-6
5
See Pic. 5-4.
To use any stored value, press the corresponding memory button and confirm by pressing
. The cutter will move by the selected value.
NOTE:
If the “Check real size” light starts blinking during normal operation
of the Setworks, press and hold the
button. Measure and enter
the distance between the bottom knife and the moulder bed exact to 0.1
mm. For example: if you want to enter 250mm - press
2-5-0-0
without a
pause and confirm by pressing
.
PIC. 5-4
ENTER
SET
REAL SIZE
SAVE