MAINTENANCE
Safety Devices Inspection
4
4-14
MHdoc012819
4.13 Safety Devices Inspection
HR Safety Devices Inspection
Before beginning a shift, the following safety devices of the HR resaw should always be
checked:
E-STOP button circuit - control box
E-STOP button circuit - fence
Safety switch circuit - 1-6 saw heads
Motor brake and its circuit
1. Control box and main electric box E-STOP circuit inspection
Start the main motor;
Push the E-STOP button located on the control box. The motor should stop.
It should not be possible to restart the motor until the E-STOP is released.
Push the E-STOP button located on the main control box. The motor should stop.
It should not be possible to restart the motor until the E-STOP is released.
FIG. 4-16
Control Box
E-STOP
Button
Main Electric
Box E-STOP
Button