Operation
Electrical Requirements (US Version Only)
2
2-11
MHdoc012819
Operation
Locate the air assembly at the right side of the machine. Connect the incoming
air supply line to the fitting. Make sure the air gauge indicates 0,6MPa (6bar)
Adjust the pressure if needed. To adjust the pressure, lift the black cap located
behind the air gauge. Turn the cap clockwise to increase pressure, turn the cap
counterclockwise to decrease pressure. Push the cap down to secure when
adjustment is complete. Air supply cut-off valve should be used to disconnect air
supply and release compressed air from the pneumatic system. Set the cut-off
valve to “SUP.” position for normal operation or to “Exh.” to release compressed
air.
WARNING!
Disconnect air supply and release compressed
air from the air system before servicing the saw! Failure to
do so may result in serious injury.
See Figure 2-8.
Electrical Requirements (US Version Only)
DANGER!
Make sure all electrical installation, service
and/or maintenance work is performed by a qualified
electrician and is in accordance with applicable electrical
codes.
6
18.5kW (E25)
109.5kW at
230/400V 50Hz
126kW at
460V 60Hz
200
0 AWG/ 50
FIG. 2-8
TABLE 2-1
Pressure Adjusting Gauge
Air Supply Cut-OFF Valve
Air Supply
Connection
Содержание HR700 Series
Страница 1: ......
Страница 2: ......
Страница 35: ...Operation Electrical Requirements US Version Only Operation MHdoc012819 2 14 2 figure below FIG 2 9 ...