3200NT Timer

  6

System Operations

System 4

Time Clock (1 Valve)

During normal operation the 

Time of Day

 display may be viewed at all times. The control operates normally 

until the number of days since the last regeneration reaches the 

Regeneration Day Override

 setting. Once 

this occurs, a 

Regeneration Cycle

 initiates at the preset 

Regeneration Time

.

Meter Delayed (1 Valve)

During normal operation the 

Time of Day

 display alternates with the 

Volume Remaining

 display

(gallons or m

3

).

— As treated water is used, the 

Volume Remaining

 display counts down from the calculated system 

capacity.

— The system monitors the volume of water used. When the system calculates that there is not a sufficient 

capacity for the next day’s operation, a regeneration cycle is initiated at the preset regeneration time.

— Water flow through the valve is indicated by the Flow Dot that flashes in a direct relationship to flow rate.

Meter Immediate (1 Valve)

During normal operation the 

Time of Day

 display alternates with the 

Volume Remaining

 display

(gallons or m

3

).

— As treated water is used, the 

Volume Remaining

 display counts down from the calculated system 

capacity to zero or (----). When this occurs a 

Regeneration Cycle

 is started.

— Water flow through the valve is indicated by the Flow Dot that flashes in a direct relationship to flow rate.

System 5

Interlock (2 – 4 Valves)

During normal operation the 

Time of Day

 display alternates with the 

Volume Remaining

 display

(gallons or m

3

).

— As treated water is used, the 

Volume Remaining

 display counts down from the calculated system 

capacity to zero or (----). When this occurs a 

Regeneration Cycle

 queues.

— If no other valve is in 

Regeneration

 the valve sends a lock command and starts a 

Regeneration Cycle

.

— If another valve is in 

Regeneration

 (i.e. the system is already locked) the valve remains 

In Service

 with 

Regeneration

 queued until other valves complete 

Regeneration

. Then the system locks and 

Regeneration

 begins.

— Water flow through the valve is indicated by the Flow Dot that flashes in a direct relationship to flow rate.

System 6

Series (2 – 4 Valves)

During normal operation the 

Time of Day

 display alternates with the 

Volume Remaining

 display

(gallons or m

3

). The 

Volume Remaining

 is the total volume for all units in the system.

— As treated water is used, the 

Volume Remaining

 display counts down from the calculated system 

capacity to zero or (----). When this occurs a 

Regeneration Cycle

 queues.

— If no other valve is in regeneration the lead valve sends a lock command and starts a 

Regeneration 

Cycle

.

— When the LEAd valve completes regeneration cycle the remaining valve(s) in the system regenerate 

sequentially until all valves regenerate.

— Water flow through the valve is indicated by the Flow Dot that flashes in a direct relationship to flow rate.
— LAg valve volume remaining is updated every 5 seconds from the LEAd valve.
— A manually forced regeneration (EC key) can only be done on the LEAd valve and only if the system is not 

in 

Regeneration

.

Содержание 3200NT

Страница 1: ...3200NT Timer Service Manual Valve Serial Number Valve Position 1 LEAd 2 LAg 3 LAg 4 LAg 41151 NT001 1 IMPORTANT Fill in pertinent information on page 3 for future reference ...

Страница 2: ...mming Mode 9 Timer Operation Display Definitions and Examples 10 Timer Diagnostics Display Definitions and Examples 11 Power Head Assembly Parts List 2750 2850 2900 Upper Drive and 2900 Lower Drive 13 Power Head Assembly 3150 3900 Upper Drive and 3900 Lower Drive 14 Power Head Assembly Parts List 3150 3900 Upper Drive and 3900 Lower Drive 15 2750 2850 Timer Wiring Diagram 16 3150 Timer Wiring Diag...

Страница 3: ... 7 Alternating 9 Alternating Valve Position LEAd or LAg Remote Signal Start Off or On Signal Time needed _______ Minutes Display Format US Gallons or m3 Unit Capacity _______________ Grains or Degrees Capacity Safety Factor Zero or ____ Regeneration Cycle Step 1 ____ Minutes Regeneration Cycle Step 2 Off or ____ Minutes Regeneration Cycle Step 3 Off or ____ Minutes Regeneration Cycle Step 4 Off or...

Страница 4: ...es driving to this regeneration step position Once all regeneration steps are complete the timer returns to In Service and resumes normal operation Example Start a Regeneration Tonight With metered delayed timers press the Extra Cycle button momentarily The In Service indicator dot flashes and starts a Regeneration tonight at the programmed Regeneration Time Day Regeneration Timer During normal op...

Страница 5: ...ation are delayed The timer upon power re application resumes normal operation from the point that it was interrupted NOTE An inaccurate Time of Day display may indicate a power outage Remote Lockout The timer does not allow the unit system to go into Regeneration until the Regeneration Lockout Input signal to the unit system is cleared This requires a contact closure to activate The recommended g...

Страница 6: ...e of Day display alternates with the Volume Remaining display gallons or m3 As treated water is used the Volume Remaining display counts down from the calculated system capacity to zero or When this occurs a Regeneration Cycle queues If no other valve is in Regeneration the valve sends a lock command and starts a Regeneration Cycle If another valve is in Regeneration i e the system is already lock...

Страница 7: ...ued until the other valve goes into standby The exhausted valve goes into standby after completing Regeneration All units remain In Service except those in standby or Regeneration Water flow through the valve is indicated by the Flow Dot that flashes in a direct relationship to flow rate Important System Operations Tips When programming multi unit systems program LAg units first and then LEAd unit...

Страница 8: ...M Light Off Display Screen Time of Day alternates with Process Display Example Volume Remaining Time Remaining programming information Extra Cycle Button Valve in Regeneration Light On Set Down Button Adjust Values Down Set Up Button Adjust Values Up Diagnostic Button View Flow Rate Peak Flow Rate Totalizer Hours Between Last Two Regenerations Hours Since Last Regeneration Adjustable Volume Remain...

Страница 9: ...colon between two sets of numbers identifies the Regeneration Time display Set the desired time of day that you want Regeneration to occur Press the Set Up and Set Down buttons to adjust this value Press the Extra Cycle button to proceed to the next step 4 Set Regeneration Day Override Us this display to set the maximum amount of time in days the unit can be In Service without a Regeneration For S...

Страница 10: ...ume Remaining Programming Error Remote Signal Start Signal is Communicating Remote Lock Out Signal Is On Format US Gallons Communication Error Format Metric Meter3 L Display Code X 1 000 000 Range 1 000 000 2 900 000 Timer is Locked Out t Display Code X 1000 Range 10 000 999 999 No Display Code Range 1 9 999 Zero ...

Страница 11: ...Last Regeneration Range 100 500 Display Code Range 1 199 P Display Code Range 0 500 Totalizer L Display Code X 1 000 000 Range 1 000 000 2 900 000 L Display Code X 1 000 000 Range 1 000 000 99 999 999 t Display Code X 1000 Range 10 000 999 999 t Display Code X 1000 Range 10 000 999 999 No Display Code Range 1 9 999 No Display Code Range 1 9 999 Valve Position No Display Code Lead or Lag Software V...

Страница 12: ...3200NT Timer 12 Power Head Assembly 2750 2850 2900 Upper Drive and 2900 Lower Drive Figure 2 2750 2850 2900 Upper Drive and 2900 Lower Drive Power Head Assembly ...

Страница 13: ... 1 41035 plug strain relief 6 1 40941 harness upper drive 7 1 40385 motor drive 24V 50 60 Hz 8 1 41034 transformer 120 24V US 1 41049 transformer 230V 24V European 1 41050 transformer 230V 24V Australian 9 1 40943 harness lower drive 10 1 40388 motor drive 24V 50 60 Hz 11 1 19121 08 meter cable assembly 35 1 19121 09 meter cable assembly 99 5 1 19121 10 meter cable assembly 303 5 12 2 12732 nut he...

Страница 14: ...3200NT Timer 14 Power Head Assembly 3150 3900 Upper Drive and 3900 Lower Drive Figure 3 3150 3900 Upper Drive and Lower Drive Power Head Assembly ...

Страница 15: ... strain relief 5 1 41035 plug strain relief 6 1 40941 harness upper drive 7 2 40391 motor drive 24V 50 60 Hz 8 1 41034 transformer 120V 24V 1 41049 transformer 230V 24V European 1 41050 transformer 230V 24V Australian 9 1 40943 harness lower drive 10 1 19121 08 meter cable assembly 35 1 19121 09 meter cable assembly 99 5 1 19121 10 meter cable assembly 303 5 11 2 10299 screw slotted round head 5 4...

Страница 16: ...3200NT Timer 16 2750 2850 Timer Wiring Diagram Figure 4 2750 2850 Timer Wiring Diagram System 4 Single Valve Regeneration 41187 NT035 0 ...

Страница 17: ...3200NT Timer 17 3150 Timer Wiring Diagram Figure 5 3150 Timer Wiring Diagram System 4 Single Valve Regeneration 41187 NT036 0 ...

Страница 18: ...3200NT Timer 18 2900 Timer Wiring Diagram Figure 6 2900 Timer Wiring Diagram System 4 Single Valve Regeneration 41188 NT037 0 ...

Страница 19: ...3200NT Timer 19 3900 Timer Wiring Diagram Figure 7 3900 Timer Wiring Diagram System 4 Single Valve Regeneration 41188 NT038 0 ...

Страница 20: ...e must be connected to the timer programmed as the LEAd Timer 2 A maximum cable length of 100 cable can be used between timers 3 Always connect IN communication port to the OUT communication port of the next timer Connect the last timer back to the first timer Figure 8 Network Timer System Wiring Diagram for System 5 6 7 and 9 Duplex Figure 9 Network Timer System Wiring Diagram for System 5 6 and ...

Страница 21: ... ground screw 2 Remove the screw and attach the transformer ground wire B 3 Re attach the screw Figure 11 Installing Ground Wire on Transformer 2750 2850 2900 Valves Figure 12 Installing Ground Wire on Transformer 3150 3900 Valves Item Description A ground label B ground wire from transformer C wires from transformer 41078 NT039 0 41081 NT040 0 ...

Страница 22: ...were in prior to the error and regeneration is queued according to the normal system operation If reprogramming the unit in the Master Programming Mode clears the error the volume remaining may be reset to the full unit capacity i e as though it were just regenerated NOTE System 4 units retain their normal display and do not display cErr Cause Correction A One or more units have a missing or bad c...

Страница 23: ...on is corrected all units return to the operating status they were in prior to the error and regeneration is queued according to the normal system operation If reprogramming the unit in the Master Programming Mode clears the error the volume remaining may be reset to the full unit capacity i e as though it were just regenerated NOTE System 4 units retain their normal display and do not display PEr...

Страница 24: ...P N 41093 Rev B 02 04 ...

Отзывы: