background image

 

 
NO: CT-019 

PRODUCT: 

 

H7AN, H7CN Counters, H5CN Timers 

DATE:  May 2014 

TYPE:  

Partial Discontinuation Notice 

Select Models of H7AN and H7CN Counters and H5CN 
Timers to be Discontinued March 2015 

Last order date

:  March 2015 

Note: Date is subject to change based on 
raw materials and components 
availability at the factory. 
 
Legacy digital counters (1/4 DIN size 
H7AN and 1/16 DIN size H7CN) and 
timers (1/16 DIN size H5CN) will be 
streamlined to focus on models with 
steady sales:  100-240 VAC models 
and those with backup power for 
memory protection. 

Affected Parts 

Product discontinuation 

 

Recommended replacement 

H7AN-E4D DC12-24 

H7AN-E4D AC100-240 

H7AN-E4DM DC12-24 

H7AN-E4DM AC100-240 

H7AN-ET4 AC100-240 

H7AN-ET4M AC100-240 

H7AN-ET4 DC12-24 

H7AN-ET4M AC100-240 

H7AN-ET4M DC12-24 

H7AN-ET4M AC100-240 

H7AN-R6D DC12-24 

H7AN-R6D AC100-240 

H7AN-RT6 DC12-24 

H7AN-RT6 AC100-240 

H7AN-RT8 AC100-240 

H7AN-RT8M AC100-240 

H7AN-RT8 DC12-24 

H7AN-RT8M DC12-24 

H7AN-T4 DC12-24 

H7AN-T4 AC100-240 

H7AN-W4D DC12-24 

H7AN-W4D AC100-240 

H7AN-WE4D DC12-24 

H7AN-WE4D AC100-240 

H7AN-WE4DM DC12-24 

H7AN-WE4DM AC100-240 

H7CN-BHN DC12-48 

H7CN-BHN AC100-240 

H7CN-YHNS AC100-240 

H7CN-YHNS DC12-48 

H5CN-XBC AC100-240 

H5CN-XBN AC100-240 

H5CN-XBNS DC12-48 

H5CN-XANS DC12-48 

H5CN-XCNM DC24 

H5CN-XCNM AC100-240 

H5CN-XDNM DC24 

H5CN-XDNM AC100-240 

H5CN-YCNM AC100-240 

H5CN-YCN AC100-240 

 

 

Summary of Contents for H5CN

Page 1: ...ion Recommended replacement H7AN E4D DC12 24 H7AN E4D AC100 240 H7AN E4DM DC12 24 H7AN E4DM AC100 240 H7AN ET4 AC100 240 H7AN ET4M AC100 240 H7AN ET4 DC12 24 H7AN ET4M AC100 240 H7AN ET4M DC12 24 H7AN ET4M AC100 240 H7AN R6D DC12 24 H7AN R6D AC100 240 H7AN RT6 DC12 24 H7AN RT6 AC100 240 H7AN RT8 AC100 240 H7AN RT8M AC100 240 H7AN RT8 DC12 24 H7AN RT8M DC12 24 H7AN T4 DC12 24 H7AN T4 AC100 240 H7AN...

Page 2: ...mended replacement supply voltage is changed to DC12 48V When replacing H5CN XBC to the recommended replacement operating mode is changed When replacing H5CN XBNS to the recommended replacement rated time is changed When replacing H5CN XCNM and H5CN XDNM to the recommended replacement supply voltage is changed to AC100 240V When replacing H5CN YCNM to the recommended replacement backup power of me...

Page 3: ...ion of Power Supply Polarity for DC powersupply Terminal 1 Terminal 2 H7AN E4D AC100 240 H7AN E4DM AC100 240 H7AN ET4M AC100 240 H7AN R6D AC100 240 H7AN RT6 AC100 240 H7AN T4 AC100 240 H7AN W4D AC100 240 H7AN WE4D AC100 240 H7AN WE4DM AC100 240 Connection of Power Supply H7CN BHN DC12 48 Connection of Power Supply H7CN BHN AC100 240 Connection of Power Supply H7CN YHNS AC100 240 Connection of Powe...

Page 4: ...y is correct H5CN XCNM AC100 240 H5CN XDNM AC100 240 Connect the timer so that the required supply voltage can be applied across terminals and H5CN YCNM AC100 240 Connection of Power Supply H5CN YCN AC100 240 Use the socket P2CF 08 E and P3G 08 PIN type is changed to 8 pin Connection of Power Supply H5CN YCNM AC100 240 Connection of Load Circuit H5CN YCN AC100 240 Connection of Load Circuit Connec...

Page 5: ...ly voltage DC12 24V permissible ripple 20 max AC100 240V 50 60 Hz Item Product discontinuation Model H7CN Recommended replacement Model H7CN H7CN BHN DC12 48 H7CN BHN AC100 240 Supply voltage DC12 48V permissible ripple 20 max AC100 240V 50 60 Hz common use Item Product discontinuation Model H7CN Recommended replacement Model H7CN H7CN YHNS AC100 240 H7CN YHNS DC12 48 Supply voltage AC100 240V 50 ...

Page 6: ...g figure However if selecting no memory backup in specification selection switches for backup power of memory protection the operation is performed same as product discontinuation H7AN ET4 AC100 240 H7AN ET4 DC12 24 Arrangement and function of specification selection switches Note1 These settings are the defaults for the specification selection switches H7AN ET4M AC100 240 Arrangement and function...

Page 7: ...hes Note1 These settings are the defaults for the specification selection switches H5CN XBC AC100 240 Operating mode Digital display returns to the initial setting once the set time is up The output signal is generated repeatedly during the one shot time H5CN XBN AC100 240 Operating mode The control output and digital display after the set time is up are held until a reset input is applied H5CN XB...

Page 8: ...scontinuation Recommended replacement H5CN YCNM AC100 240 The timer status during momentary power failures is shown as follows H5CN YCN AC100 240 The timer status during momentary power failures is shown as follows ...

Page 9: ...mounting adapter Model Y92F 30 Flush mounting adapter Recommended replacement H5CN YCN AC100 240 No external dimension changes of timer for product discontinuation and recommended replacement Dimensions with mounting adapter Model Y92F 30 Flush and surface mounting adapters ...

Page 10: ...cting socket Flush and surface mountings Flush mounting Specifications and prices in this product news are as of the issue date and are subject to change without notice Only main changes in specifications are described in this document Please be sure to read the relevant catalogs datasheets product specifications instructions and manuals for precautions and necessary information when using product...

Reviews: