13
EXCHANGING LAMPS
1. Turn the unit off
(#26)
and disconnect the power cord!
2. Press the
lamp exchange cover
3. Turn
4. Change the defective lamp (or both lamps)
Before changing the lamp allow it to cool down or use a cloth to avoid burning your fingers!
When pressing a new lamp into the socket use a cloth to prevent fingerprints on the lamp!
(#11)
on the right side. This releases the cover and it swings down.
the two quick locks with a coin and swing the lampchanger hinge down.
Only use long life 12 V/100 W halogen lamps (socket: GY 6,35), types: Philips 7724, Osram HLX 64623, Ansi EVA,
LIF M/28, NAED 54052 etc. These are relatively inexpensive standard OHP lamps.
AUTOMATIC LAMP CHANGER
If the unit gets too hot (improper ventilation or air extraction) a built in thermostat will switch off the light of the
Visualizer. Verify that proper ventilation and air extraction is available and allow the unit to cool.
THERMOSTAT
LIGHT
18
EXCHANGING A FUSE
Before changing a fuse disconnect the power cable. The fuses
(#27)
are
situated in a fuse holder behind a small lid beside the power socket and the
main power switch. It can easily be opened with a small screwdriver etc.
Please make sure that the fuses are put in correctly.
The type of fuse is: T 3,15A. Do not use any other type !
Change the fuse for a new one and switch the unit on again. If the fuse fails again contact your Visualizer dealer!
With most Visualizers the fuse never fails during the whole lifetime of the unit.
Turn the quick locks
Change the lamp
Press here
The VZ-C10 is fitted with an automatic lamp changer. If one lamp fails, there is no need to replace it immediately, as
the automatic lamp changer automatically switches to the second lamp. When the unit changes lamps there is an
on-screen message saying: "Changing lamp".
When switching the unit on the Visualizer checks if both lamps are working. If one lamp fails there will be an on
screen message for a couple of seconds displaying "Change lamp".
This prevents a user from forgetting to change a defective lamp.
If a lamp is not fully defective, but worn out and as a result the light output is quite weak, you can manually switch to
the second lamp by pressing the LIGHT key
(#18)
for 2 seconds.