Wolf Cooktop Ventilation
102
2
3
/
8
"
(60)
30"
(762)
9
1
/
16
"
(230)
26
1
/
4
"
(667)
1
1
/
2
"
(38)
DEPTH OF CHIMNEY
Downdrafts
30"
(762)
DOWNDRAFT
36"
(914)
32
1
/
4
"
(819)
2
3
/
8
"
(60)
9
1
/
16
"
(230)
1
1
/
2
"
(38)
DEPTH OF CHIMNEY
36"
(914)
DOWNDRAFT
45
1
/
2
"
(1156)
41
1
/
4
"
(1048)
2
3
/
8
"
(60)
9
1
/
16
"
(230)
1
1
/
2
"
(38)
DEPTH OF CHIMNEY
45"
(1143)
DOWNDRAFT
Planning Information
Wolf downdraft systems can be used with Wolf framed
induction, framed electric and gas cooktops and some
integrated modules. Downdrafts cannot be installed with
unframed induction and unframed electric cooktops, and
steamer and fryer modules. They are not recommended
for use with the grill module. A downdraft can also be
used with sealed burner rangetop models SRT304 and
SRT366. An accessory trim kit is necessary for this instal-
lation. Contact your authorized Wolf dealer for details.
IMPORTANT NOTE:
To install a downdraft with a Wolf
cooktop, you must allow for a minimum 25
1
/
8
"
(638)
flat
counter space from front to back. A countertop with a
raised lip or backsplash may not allow enough space for
proper installation.
Installation of the remote-mounted control module must
be within 10'
(3 m)
of the downdraft assembly and a
minimum of 4"
(102)
from the outer edge of cooktop
element or burner.
Downdraft models DD30I, DD36I and DD45I include a 500
CFM internal blower. In-line and remote blower assemblies
are available for models DD30R, DD36R and DD45R
through your authorized Wolf dealer. For local dealer infor-
mation, visit the find a showroom section of our website,
wolfappliance.com.
The blower will vary in size and is dictated by the cooking
unit, the volume of air that needs to be moved and the
length of the duct run. Refer to ventilation recommenda-
tions on pages 113–115.
Downdrafts with an internal blower have a 3
1
/
4
"
(83)
x 10"
(254)
duct and for remote blower models, a 3
1
/
4
"
(83)
x 14"
(356)
duct. All downdrafts have an adjustable discharge.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
ELECTRICAL REQUIREMENTS
Certain installations may require that the electrical supply
be placed in an adjacent cabinet.
Electrical Requirements
DOWNDRAFT VENTILATION
Electrical Supply
Grounded, 120 V AC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
2
1
/
2
'
(.8 m)