Wolf Integrated Modules
55
wolfappliance.com/specs
Planning Information
When multiple cooktops or modules are installed side
by side, the countertop cut-out dimension is determined
by adding the overall width of each product plus
1
/
4
"
(6)
for
each filler strip, then subtracting 1"
(25)
. Refer to the chart
below for typical configurations.
Example—To determine the countertop cut-out for a
30"
(762)
cooktop and 15"
(381)
module with one filler strip:
30" + 15" +
1
/
4
" – 1" = 44
1
/
4
"
The optional filler strip is available through your authorized
Wolf dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
IMPORTANT NOTE:
Wolf does not recommend the use of
downdraft ventilation with the grill, steamer or fryer
modules.
ELECTRICAL REQUIREMENTS
When multiple cooktops or modules are installed side by
side, each must have its own separate electrical supply.
GAS SUPPLY REQUIREMENTS
A gas supply line of
3
/
4
"
(19)
rigid pipe must be provided
to the gas module. If local codes permit, a certified, 3'
(.9 m)
long,
1
/
2
"
(13)
or
3
/
4
"
(19)
ID flexible metal appliance con-
nector is recommended to connect the units
1
/
2
" NPT
female inlet to the gas supply line.
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas modules will function up to an altitude of
10,250'
(3124 m)
without adjustment and LP gas modules
will function up to 8,600'
(2621 m)
. If the installation
exceeds these elevations, contact your authorized Wolf
dealer for a high altitude conversion kit.
Multiple Cooktops
COUNTERTOP CUT-OUT
WIDTH
2 Modules
29
1
/
4
"
(743)
3 Modules
44
1
/
2
"
(1130)
4 Modules
59
3
/
4
"
(1518)
30"
(762)
Cooktop / 1 Module
44
1
/
4
"
(1124)
30"
(762)
Cooktop / 2 Modules
59
1
/
2
"
(1511)
36"
(914)
Cooktop / 1 Module
50
1
/
4
"
(1276)
2
1
/
2
"
(64) min
19
1
/
4
"
(489)
CUT-OUT
DEPTH
CUT-OUT WIDTH
FRONT OF COUNTERTOP
Countertop cut-out.
Electrical Requirements
ELECTRIC MODULES
Electrical Supply
Grounded 3-wire, 240/208 V AC, 60 Hz
Service (IS15/S, IF15/S)
15 amp dedicated circuit
(CT15I/S, CT15E/S, IG15/S)
20 amp dedicated circuit
Conduit
Flexible 4'
(1.2 m)
GAS MODULES (CT15G/S, IM15/S)
Electrical Supply
120 V AC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
6'
(1.8)
Gas Supply Pressure
NATURAL GAS
Gas Supply Pressure
5"
(12.5 mb)
WC
Min Line Pressure
7"
(17.5 mb)
WC
Max Pressure to Regulator
14"
(34.9 mb)
WC, .5 psi
(3.5 kPa)
LP GAS
Gas Supply Pressure
10"
(25 mb)
WC
Min Line Pressure
11"
(27.4 mb)
WC
Max Pressure to Regulator
14"
(34.9 mb)
WC, .5 psi
(3.5 kPa)