9 Commissioning
FWL-PushPull-30 (TwinUnit)
7100904 | 202202
WOLF GmbH | 51
Bol
d
Factory settings
LED flashes quickly
LED flashes slowly
FWL-PushPull-30 RC
(TwinUnit) LEDs
Parameters
Set value Setting / description
The blue oper-
ating mode
LED flashes
1x per cycle
Duration of
intermittent
ventilation/
ventilation level
1
2
3
5 minutes (red LED 1x)
10 minutes (red LED 2x)
30 minutes (red LED 3x)
Parameters for the duration of the manual de-
humidification function (level 5) and the dura-
tion of the ventilation level when overriding de-
mand-driven operation are set here (factory
setting 10 minutes).
The blue oper-
ating mode
LED flashes
2x per cycle
Sleep function
1
2
3
30 minutes (red LED 1x)
60 minutes (red LED 2x)
90 minutes (red LED 3x)
The duration of the sleep function (level 0) is
parameterised here
(factory setting 60 minutes).
The blue oper-
ating mode
LED flashes
3x per cycle
Filter runtime
1
2
3
4
2 months (red LED 1x)
3 months (red LED 2x)
6 months (red LED 3x)
Reset filter runtime (red LED 4x)
.The filter runtime is parameterised here (fact-
ory setting 6 months).
The blue oper-
ating mode
LED flashes
4x per cycle
Single-room
ventilation unit
1
2
Operation in pairs (red LED 1x
)
single-room ventilation unit (red LED 2x)
If there are reception problems with the slave
or master device, the
FWL-PushPull-30 RC
(TwinUnit)
unit can be enabled as a single-
room ventilation unit.