Page 47
4
Disconnect the wire connectors from the temperature probe
socket.
Temperature
Probe Socket
TEMPERATURE PROBE SOCKET INSTALLATION
After installing the temperature probe socket, install:
1
2
3
4
5
.
Install the Temperature Probe Socket
1
Connect the wire connectors onto the temperature probe
socket.
2
Install the temperature probe socket into the oven cavity.
3
Replace the oven insulation.
4
Use an 11 mm combination wrench to install the nut of the
temperature probe socket, which is located on the inside of
the oven cavity.
BAKE ELEMENT REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the bake element, first
remove:
1
2
3
4
5
Remove the Bake Element
1
Use needle-nose pliers to disconnect the wire connectors
from the bake element.
2
Use a T-20 Torx bit to remove the screws from the bake
element.
3
Use a T-20 Torx bit to remove the screws from the bottom
support at the rear on the unit.
4
Use a T-20 Torx bit to remove the bottom screws from the
side panels.
5
Place the oven on one side.
6
Use a T-20 Torx bit to remove the screws from the side
panel.
7
Remove the side panel.
8
Use needle-nose pliers to remove the plug wire connectors
from the terminal block.
9
Use a T-20 Torx bit to remove the screw from the center of
the bottom plate.
10
Bend the back panel and remove the bottom plate with
cord.
11
Remove the bottom plate support and insulation pad.
12
Fold back the side insulation, exposing the two tabs locking
the bottom support to the oven cavity.
13
Bend the two tabs straight.
14
Bend the bottom support over the tabs and pull the side of
the bottom support toward the bottom of the unit.
15
Remove the bake element from the unit.
TIP: To remove the bottom support, repeat steps 5 through 7 on
the opposite side of the unit.
E Series SO24 (SWS 13543126)
Back Component Removal and Installation
REMOVE THE TEMPERATURE PROBE SOCKET (continued)
service.subzero.com
827705 REVA 01/2019
46