e-Mail: [email protected]
http://mgkg.woehler.de
41
Wöhler DC 17 Pressure Computer
ENGLISH
3. Operation
Always check the device visually before use to ensure that it is only operated
in perfect and functional condition. After switching on the device, a self-test
is executed. After that date and time is indicated on the display. If the logger
function of the device was enabled beforehand, the word
„Log“
, followed by
current measuring and memory values, will be indicated before the device
switches off again. As long as the cursor set on the subprogram P=0 is flas-
hing, no hose may be connected and no differential pressure may be applied,
since the device performs a stabilization cycle and determines its zero
point
. After that, the display indicates the current differential pressure.
Fig. 3.1: Selecting the
Hydr.-kv
menu
If overpressure is present at the hose connection marked with
(+)
, or if a va-
cuum is present at the hose connection marked with
(-)
, a positive differential
pressure will be indicated on the display. If the differential pressure exceeds
1,100.0 hPa, the device switches automatically to the upper measuring range
(up to 20,000 hPa).
The following section describes the basic functions of the individual menu
items.
3. Operation